Netra 240
375-3178 |
375-3120 |
Assy 375-3148 Tomatillo 2.3 0MB USIIIi FRU
1× 1.280GHz w Fan/Heatsink Option 7427A October 2003 |
Assy 375-3148 Tomatillo 2.3 0MB USIIIi FRU
2× 1.280GHz w Fan/Heatsink Option 7428A October 2003 |
375-3251 |
375-3247 |
Assy 375-3246 Tomatillo 2.3 0MB USIIIi FRU
1× 1.280GHz w Fan/Heatsink Option 7427A March 2005 |
Assy 375-3246 Tomatillo 2.3 0MB USIIIi FRU
2× 1.280GHz w Fan/Heatsink Option 7428A March 2005 |
LOCATION |
PINS |
SETTING |
DESCRIPTION |
JP1 |
1-2 3-4 9-10 |
In In In |
1.4V Core VID[4:0] (00110)
1.4V Core VID[4:0] (00110)
1.4V Core VID[4:0] (00110) |
JP2 |
1-2 1-2 |
Out In |
ALOM Flash Normal (default)
ALOM Flash Recovery |
JP3 |
1-2 1-2 |
Out In |
ALOM Normal (default)
ALOM Reset |
JP4 |
1-2 3-4 |
In In |
1.280GHz CONFIG[2:0] (100)
1.280GHz CONFIG[2:0] (100) |
JP5 |
1-2 1-2 |
Out In |
ATAPI Master - CSEL Open (default)
ATAPI Slave - CSEL Grounded |
JP6 |
1-2 2-3 |
In/Out In |
OBP Flash Select (default)
ROMBO Select |
JP8 |
1-2 2-3 |
In In |
Normal CMOS (default)
Clear CMOS |
JP10 |
1-2 1-2 |
Out In |
PS_ON# (default)
PS_ON# Override |
JP11 |
1-2 1-2 |
Out In |
OBP Flash Write Enabled (default)
OBP Flash Write Protected |
JP12 |
1-2 1-2 |
Out In |
ALOM Console Normal (default)
ALOM Console Bypass |
JP13 |
1-2 2-3 |
In/Out In |
OBP Flash Normal (default)
OBP Flash Recovery |
Netra 240 Codename: Enchilada 19 |
Notes
- The minimum operating system is Solaris 8 7/03.
- ALOM update is available at
Firmware Downloads.
- The JBUS clock is 160MHz and the Memory clock is 128MHz with 1.280GHz CPUs.
Memory Notes
- Bank, Rank, DIMM, and XOR Interleaving is supported.
- UltraSPARC IIIi supports single bank and dual bank DDR DIMMs.
- Two DIMMs of the same bank size (single or dual) and memory size form a
bank.
- The minimum requirement is two DIMMs in any Bank (B0/D0/D1 or B1/D0/D1).
- Only CPU 0 DIMMs are access1ble in a single CPU system (CPU 0).
- Memory is mapped globally and is access1ble by either CPU in a dual-CPU
system.
- Each processor interfaces with its own dedicated block of DDR-1 SDRAM DIMMs.
- Memory error reporting identifies a failing Bank, not a single failing DIMM.
Motherboard Notes
- Motherboard 375-3148 is without Memory or UltraSPARC IIIi.
- Motherboard 375-3246 is without Memory or UltraSPARC IIIi.
- The FRUs include Motherboard (375-3148 or 375-3246), US IIIi, and
Fan/Heatsink 370-5126 or 370-7786.
- Remove the Fan from the Heatsink prior to System Board installation.
See 817-4048 below.
- Motherboard replacement requires a 3/16 Hex driver, #2 Phillips driver,
and a Minus driver with a maximum thickness of 0.660 mm (0.026").
References
-
Netra 240 Server Installation Guide, 817-2698.
-
Netra 240 Server Service Manual, 817-2699.
-
Netra 240 Server System Administration Guide, 817-2700.
-
Netra 240 Server Release Notes, 817-3142.
-
Sun Advanced Lights Out Manager Software User's Guide for the Netra 240 Server, 817-3174.
-
Heatsink Field Replaceable Unit Installation Guide, 817-4048.
Netra 240
375-3261 |
375-3227 |
Assy 375-3228 Tomatillo 2.3 0MB USIIIi FRU
1× 1.503GHz w Heatsinks Option 7437A February 2005 |
Assy 375-3228 Tomatillo 2.3 0MB USIIIi FRU
2× 1.503GHz w Fans/Heatsinks Option 7438A February 2005 |
Netra 210 / Netra 240
375-3359 |
375-3360 |
375-3471 |
375-3472 |
Assy 375-3325 Tomatillo 2.3 0MB USIIIi FRU
1× 1.503GHz w Fanless Heatsink
Option 7437A-4 N210/N240 December 2005
L
1× 1.336GHz on N210
see Jumper JP4 below |
Assy 375-3325 Tomatillo 2.3 0MB USIIIi FRU
2× 1.503GHz w Fanless Heatsink
Option 7438A-4 N210/N240 December 2005
L
2× 1.336GHz on N210
see Jumper JP4 below |
Assy 375-3325 Tomatillo 2.3 0MB USIIIi FRU
1× 1.336GHz w Fanless Heatsink
Option 8218A-Z N210 June 2006
L |
Assy 375-3325 Tomatillo 2.3 0MB USIIIi FRU
2× 1.336GHz w Fanless Heatsink
Option 8219A-Z N210 June 2006
L |
375-3473 |
375-3474 |
375-3483 |
375-3484 |
R06 Assy 375-3459 Tomatillo 2.3 0MB USIIIi FRU
1× 1.336GHz w Fanless Heatsink
N210 October 2006 L |
R06 Assy 375-3459 Tomatillo 2.3 0MB USIIIi FRU
2× 1.336GHz w Fanless Heatsink
N210 October 2006 L |
R06 Assy 375-3459 Tomatillo 2.3 0MB USIIIi FRU
1× 1.503GHz w Fanless Heatsink
N240 October 2006 L |
R06 Assy 375-3459 Tomatillo 2.3 0MB USIIIi FRU
2× 1.503GHz w Fanless Heatsink
N240 October 2006 L |
LOCATION |
PINS |
SETTING |
DESCRIPTION |
JP1 |
1-2 3-4 9-10 |
In In In |
1.4V Core VID[4:0] (00110)
1.4V Core VID[4:0] (00110)
1.4V Core VID[4:0] (00110) |
JP2 |
1-2 1-2 |
Out In |
ALOM Flash Normal (default)
ALOM Flash Recovery |
JP3 |
1-2 1-2 |
Out In |
ALOM Normal (default)
ALOM Reset |
JP4 (N210) |
5-6 |
In |
1.336GHz CONFIG[2:0] (011) * |
JP4 (N240) |
1-2 5-6 |
In In |
1.503GHz CONFIG[2:0] (010)
1.503GHz CONFIG[2:0] (010) |
JP5 |
1-2 1-2 |
Out In |
ATAPI Master - CSEL Open (default)
ATAPI Slave - CSEL Grounded |
JP6 |
1-2 2-3 |
In/Out In |
OBP Flash Select (default)
ROMBO Select |
JP8 |
1-2 2-3 |
In In |
Normal CMOS (default)
Clear CMOS |
JP10 |
1-2 1-2 |
Out In |
PS_ON# (default)
PS_ON# Override |
JP11 |
1-2 1-2 |
Out In |
OBP Flash Write Enabled (default)
OBP Flash Write Protected |
JP12 |
1-2 1-2 |
Out In |
ALOM Console Normal (default)
ALOM Console Bypass |
JP13 |
1-2 2-3 |
In/Out In |
OBP Flash Normal (default)
OBP Flash Recovery |
* Maximum speed for the Netra 210 is 1.336GHz.
Netra 240 Codename: Enchilada 19 |
Notes
- The minimum operating system is Solaris 8 2/04, Solaris 9 9/04, or
Solaris 10.
- ALOM update is available at
Firmware Downloads.
- The JBUS clock is 167MHz and the Memory clock is 111MHz with 1.336GHz CPUs.
- The JBUS clock is 167MHz and the Memory clock is 125MHz with 1.503GHz CPUs.
Memory Notes
- Bank, Rank, DIMM, and XOR Interleaving is supported.
- UltraSPARC IIIi supports single bank and dual bank DDR DIMMs.
- Two DIMMs of the same bank size (single or dual) and memory size form a
bank.
- The minimum requirement is two DIMMs in any Bank (B0/D0/D1 or B1/D0/D1).
- Only CPU 0 DIMMs are access1ble in a single CPU system (CPU 0).
- Memory is mapped globally and is access1ble by either CPU in a dual-CPU
system.
- Each processor interfaces with its own dedicated block of DDR-1 SDRAM DIMMs.
- Memory error reporting identifies a failing Bank, not a single failing DIMM.
375-3261 / 375-3227 Motherboard Notes
- Motherboard 375-3228 is without Memory or UltraSPARC IIIi.
- F375-3261 includes Assembly 375-3228, US IIIi, and
Heatsink w/o Fan 370-7784.
- F375-3227 includes Assembly 375-3228, US IIIi, and
Fan/Heatsink 370-7016 or 370-7786.
- FRUs F375-3261 and F375-3227 include Fan/Heatsink removal tool 345-1439.
- Remove the Fan from the Heatsink prior to System Board installation.
See 817-4048 below.
- Motherboard replacement requires a 3/16 Hex driver, #2 Phillips driver,
and a Minus driver with a maximum thickness of 0.660 mm (0.026").
375-3359 / 375-3360 / 375-3471 / 375-3472 Motherboard Notes
- Motherboard 375-3325 is without Memory or UltraSPARC IIIi.
- FRUs include Assembly 375-3325, US IIIi, and Fanless Heatsink 371-0984.
- Motherboard replacement requires a 3/16 Hex driver, #2 Phillips driver,
and a Minus driver with a maximum thickness of 0.660 mm (0.026").
375-3473 / 375-3747 / 375-3483 / 375-3484 Motherboard Notes
- Motherboard 375-3459 is without Memory or UltraSPARC IIIi.
- FRUs include Assembly 375-3459, US IIIi, and Fanless Heatsink 371-0984.
- Motherboard replacement requires a 3/16 Hex driver, #2 Phillips driver,
and a Minus driver with a maximum thickness of 0.660 mm (0.026").
References
-
Netra 210 Server System Administration Guide, 819-2749.
-
Netra 210 Server Service Manual, 819-2750.
-
Netra 210 Server Product Notes, 819-2751.
-
Netra 240 Server Installation Guide, 817-2698.
-
Netra 240 Server Service Manual, 817-2699.
-
Netra 240 Server System Administration Guide, 817-2700.
-
Netra 240 Server Release Notes, 817-3142.
-
Sun Advanced Lights Out Manager Software User's Guide for the Netra 240 Server, 817-3174.
-
Heatsink Field Replaceable Unit Installation Guide, 817-4048.
|