Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



Netra CP2140

Codename: Othello+

CP2140S-650

Netra CT 410 / Netra CT 810
Sun Fire 12K / 15K / E20K / E25K

501-6358 501-6403 <=501-6416-04 <=501-6417-04 501-6529
0MB 650MHz
Service FRU
1GB 650MHz
501-6358 with
2× 375-3025
Lucent FRU
2GB 650MHz
501-6358 with
2× 375-3026
4GB 650MHz
501-6358 with
2× 375-3114
2GB 650MHz
501-6358 with
2× 375-3125
Lucent FRU
501-6772 501-6967 501-6416-05 501-6417-05 501-6913
0MB 650MHz
Service FRU
1GB 650MHz
501-6772 with
2× 375-3025
Lucent FRU
2GB 650MHz
501-6772 with
2× 375-3026
4GB 650MHz
501-6772 with
2× 375-3114
2GB 650MHz
501-6772 with
2× 375-3125
Lucent FRU

CP2140S-650-1GBLU

Netra ct 400 / Netra ct 800

501-6926 501-6927
0MB 650MHz
FAB 270-6772
No FRU
2GB 650MHz
501-6926 with
2× 375-3125
CP2140S-650-1GBLU
Lucent FRU
501-7591 501-7592
0MB 650MHz
FAB 270-7428
L
2GB 650MHz
501-7591 with
2× 375-3392
CP2140S-6502GBSWL4
L

Jumper Settings

SWITCH DIP SETTING DESCRIPTION
SW0501 1
2
On
On
SMC setting for non-HA system (default)
1
2
Off
On
SMC setting for HA system
SW1801 1
2
Off
Off
Boot Flash PROM selected (default)
1
2
On
On
User Flash PROM 1 selected
1
2
Off
On
User Flash PROM 1 and 2 selected
1
2
On
Off
ROMBO selected
SW2401 1
1
Off
On
SCSI Bus A Termination Power enabled
SCSI Bus A Termination Power disabled
2
2
Off
On
SCSI Bus B Termination Power enabled
SCSI Bus B Termination Power disabled
3
3
Off
On
SCSI Bus A Termination enabled
SCSI Bus A Termination disabled
4
4
Off
On
SCSI Bus B Termination enabled
SCSI Bus B Termination disabled

Netra ct 400 Codename: Tonga
Netra ct 800 Codename: Monte Carlo
Netra CT 410/810 Codename: Makaha
Sun Fire 12K Codename: Starkitty
Sun Fire 15K Codename: Starcat
Sun Fire E20K/E25K Codename: Amazon 20 / 25

Notes

  1. The minimum CP2140 operating system is Solaris 8 2/02.
  2. The minimum Netra CT 410/810 operating system is Solaris 9.
  3. The Sun Fire 12K/15K and E20K/25K require SMS 1.4.1 with patches.
  4. The M48T59 Snaphat TOD at U1702 is part number 100-5876.
  5. The Hostid and MAC address are in the I2C SEEPROM 100-6755 at U3207.
  6. High Availability (HA) systems use the BD_SEL, HEALTHY, and PCI-RST signals to control each slot.
  7. The 501-6926 and 501-6927 were released in August 2004 to replace the CP1500 used by Lucent in the Netra ct 400 and Netra ct 800.

Option Notes

  1. Use 512MB Memory 375-3025, Option XCP2000-MEM-512.
  2. Use 1GB Memory 375-3026, Option XCP2000-MEM-1GB.
  3. Use 1GB Memory 375-3125, Option XCP2000-MEM-1GBSW.
  4. Use 2GB Memory 375-3114, Option XCP2000-MEM-2GB.
  5. Use Rear Transition Card 375-0121, Option XCP2040-TRN.
  6. Use Rear Transition Card 375-3429, L, Option XCP2040-TRN-4.

UltraSPARC IIi Notes

  1. The 650MHz UltraSPARC IIi is similar to the 270-440MHz UltraSPARC IIi. Differences include integrated L2 Cache and SDRAM Memory Control.
  2. The 650MHz UltraSPARC IIi is based on the 500MHz UltraSPARC IIe.
  3. The 650MHz UltraSPARC IIi OBP and OS name is UltraSPARC IIe.

Reference

Netra CP2140 Technical Reference Manual, 816-4908.



Netra CP2140

Codename: Othello+

CP2140S-650-1GB-4
CP2140S-650-2GBSW4

Netra CT 410 / Netra CT 810

501-7428 501-7426 501-7427
0MB 650MHz FRU
FAB 270-7428
L
1GB 650MHz FRU
501-7428 with
2× 375-3391
CP2140S-650-1GB-4
L
2GB 650MHz FRU
501-7428 with
2× 375-3392
CP2140S-650-2GBSW4
L

Jumper Settings

SWITCH DIP SETTING DESCRIPTION
SW0501 1
2
On
On
SMC setting for non-HA system (default)
1
2
Off
On
SMC setting for HA system
SW1801 1
2
Off
Off
Boot Flash PROM selected (default)
1
2
On
On
User Flash PROM 1 selected
1
2
Off
On
User Flash PROM 1 and 2 selected
1
2
On
Off
ROMBO selected
SW2401 1
1
Off
On
SCSI Bus A Termination Power enabled
SCSI Bus A Termination Power disabled
2
2
Off
On
SCSI Bus B Termination Power enabled
SCSI Bus B Termination Power disabled
3
3
Off
On
SCSI Bus A Termination enabled
SCSI Bus A Termination disabled
4
4
Off
On
SCSI Bus B Termination enabled
SCSI Bus B Termination disabled

Netra CT 410/810 Codename: Makaha

Notes

  1. The minimum CP2140 operating system is Solaris 8 2/02.
  2. The M48T59 Snaphat TOD at U1702 is part number 100-5893.
  3. The Hostid and MAC address are in the I2C SEEPROM 101-0207 at U3207.

UltraSPARC IIi Notes

  1. The 650MHz UltraSPARC IIi is similar to the 270-440MHz UltraSPARC IIi. Differences include integrated L2 Cache and SDRAM Memory Control.
  2. The 650MHz UltraSPARC IIi is based on the 500MHz UltraSPARC IIe.
  3. The 650MHz UltraSPARC IIi OBP and OS name is UltraSPARC IIe.

Reference

Netra CP2140 Technical Reference Manual, 816-4908.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback