 4-Slot SAS/SATA Disk Backplane
 
| Workstations: | Ultra 25, 40, 40 M2, 45 |  Option 4213
| F373-0020 |  
| Assembly/FRU Backplane 373-0020
 Assy 411739300011
 PCB 316739300003
 Ultra 40 SATA Data Cable 422740700002
 Ultra 25/45 SAS/SATA Data Cable 422739300001
 Ultra 40 M2 SAS Cable Kit 422755900001
 
 |  
  
 
| Ultra 25 Codename: South Side Ultra 40 Codename: Sirius
 Ultra 40 M2 Codename: Stuttgart
 Ultra 45 Codename: Chicago
 |  Ultra 40 M2 Notes
Set the solder side switch to Master for lower backplane drives HDD0-HDD3.
Set the solder side switch to Slave for upper backplane drives HDD4-HDD7.
SATA Data Cable 422740700002 has no Sun part number and no option.SATA Data Cable 422740700002 (U40) is not included with Backplane Option 4213.
 SATA Data Cable 422739300001 (U25/U45) is not included with Backplane Option 4213.
 SATA Data Cable 422755900001 (U40 M2) is included with Backplane Option 4213.
 
The switch was added to 373-0020-02 in October 2006.
   (WO_34043)
 References
 Ultra 40 Setup Guide, 819-3951. Ultra 40 Service, Diagnostics, and Troubleshooting Manual, 819-3952. Ultra 40 Getting Started Guide, 819-3953. Ultra 40 Release Notes, 819-3954. Ultra 40 M2 Release Notes, 819-7565. Ultra 40 M2 Installation Guide, 820-0121. Ultra 40 M2 Service Manual, 820-0123. Ultra 45 and Ultra 25 Workstations Installation Guide, 819-1891. Ultra 45 and Ultra 25 Workstations Service and Diagnostics Manual, 819-1892. Ultra 45 and Ultra 25 Workstations Product Notes, 819-1893. Ultra 45 and Ultra 25 Workstations Getting Started Guide, 819-1894. 
 |