Single-Ended Fast/Wide (SWIS/S)
Workstations: |
SPARCstation 4, 5, 10, 20
Ultra 1, 1E, 2 |
Servers: |
SPARCserver 6x0MP, 1000, SPARCcenter 2000
Enterprise 3x00, 4x00, 5x00, 6x00, 10000 |
Disk Arrays: |
StorEdge S1 |
Tape Libraries: |
StorEdge L9 |
Option 1063
370-1703 |
QLogic SP1610402 |
Power
- 1.6 Amps @ +5Vdc
- 8.0 Watts maximum
Notes
- The minimum operating system is Solaris 2.3.
- The SWIS/S supports up to 15 targets on the SCSI bus.
- Do NOT mix narrow (8-bit) and wide (16-bit) SCSI devices on the same
controller under Solaris 2.3. Install Patch 101378-01.
- Warning messages are displayed if fast/wide SCSI is enabled under Solaris
2.3. Install Patch 101378-01.
- Set scsi_options=0x3f8 in the /etc/system file to
enable fast/wide transfers.
Reference
-
SBus Intelligent SCSI Host Adapter, 801-5355.
|