Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



Single-Ended Fast/Wide (SWIS/S)

Codename: Sport16

Workstations: SPARCstation 4, 5, 10, 20
Ultra 1, 1E, 2
Servers: SPARCserver 6x0MP, 1000, SPARCcenter 2000
Enterprise 3x00, 4x00, 5x00, 6x00, 10000
Disk Arrays: StorEdge S1
Tape Libraries: StorEdge L9

Option 1063

370-1703
QLogic SP1610402

Power

1.6 Amps @ +5Vdc
8.0 Watts maximum

Notes

  1. The minimum operating system is Solaris 2.3.
  2. The SWIS/S supports up to 15 targets on the SCSI bus.
  3. Do NOT mix narrow (8-bit) and wide (16-bit) SCSI devices on the same controller under Solaris 2.3. Install Patch 101378-01.
  4. Warning messages are displayed if fast/wide SCSI is enabled under Solaris 2.3. Install Patch 101378-01.
  5. Set scsi_options=0x3f8 in the /etc/system file to enable fast/wide transfers.

Reference

SBus Intelligent SCSI Host Adapter, 801-5355.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback