 Single-Ended Fast/Wide (SWIS/S)
 
| Workstations: | SPARCstation 4, 5, 10, 20 Ultra 1, 1E, 2
 |  
| Servers: | SPARCserver 6x0MP, 1000, SPARCcenter 2000 Enterprise 3x00, 4x00, 5x00, 6x00, 10000
 |  
| Disk Arrays: | StorEdge S1 |  
| Tape Libraries: | StorEdge L9 |  Option 1063
| 370-1703 |  
| QLogic SP1610402 |  
  Power
1.6 Amps @ +5Vdc
8.0 Watts maximum
 Notes
The minimum operating system is Solaris 2.3.
The SWIS/S supports up to 15 targets on the SCSI bus.
Do NOT mix narrow (8-bit) and wide (16-bit) SCSI devices on the same
    controller  under Solaris 2.3. Install Patch 101378-01.
Warning messages are displayed if fast/wide SCSI is enabled under Solaris
    2.3. Install Patch 101378-01.
Set scsi_options=0x3f8 in the /etc/system file to
    enable fast/wide transfers. 
 Reference
 SBus Intelligent SCSI Host Adapter, 801-5355. 
 |