 SCSI AdapterSPARCstorage UniPack / StorEdge UniPack
| 501-2790 |  
| 80-Pin Disk Options Fast/Wide SCSI
 |  
  Notes
The SCSI bus length on the SCSI Adapter is approximately 170 mm.
The SCSI Adapter is included with Power Supply Assembly 540-2694.
 Termination Notes
The Desktop Storage Pack requires external termination.
The SPARCstorage UniPack does not require external termination.
The Upper LED indicates termination of SCSI Data Bits D15 - D8.
The Lower LED indicates termination of SCSI Data Bits D7 - D0. 
 Reference
SPARCstorage UniPack Hardware Setup Instructions, 802-3227.
 
 SCSI AdapterStorEdge UniPack
| 501-4823 |  
| 80-Pin Disk Options Ultra/Wide SCSI
 |  
  Notes
The SCSI bus length on the SCSI Adapter is approximately 170 mm.
The SCSI Adapter is included with Power Supply Assembly 540-3732.
 Termination Notes
The Desktop Storage Pack requires external termination.
The StorEdge UniPack does not require external termination.
The Upper LED indicates termination of SCSI Data Bits D15 - D8.
The Lower LED indicates termination of SCSI Data Bits D7 - D0.
 Reference
SPARCstorage UniPack Hardware Setup Instructions, 802-3227.
 
 SCSI AdapterSPARCstorage UniPack / StorEdge UniPack
| 501-2791 |  
| CD-ROM Options Narrow SCSI Tape Options
 |   
 Notes
The SCSI bus length on the SCSI Adapter is approximately 170 mm.
The ribbon cable is soldered to the printed circuit board.
The SCSI Adapter is included with Power Supply Assembly 540-2674.
 Termination Notes
The Desktop Storage Pack requires external termination.
The SPARCstorage UniPack does not require external termination.
The Upper LED indicates termination of SCSI Data Bits D15 - D8.
The Lower LED indicates termination of SCSI Data Bits D7 - D0. 
 Reference
SPARCstorage UniPack Hardware Setup Instructions, 802-3227.
 
 SCSI AdapterSPARCstorage UniPack / StorEdge UniPack
| 501-3108 |  
| Wide SCSI Tape Options |   
 Notes
The SCSI bus length on the SCSI Adapter is approximately 170 mm.
The ribbon cable is soldered to the printed circuit board.
The SCSI Adapter is included with Power Supply Assembly 540-3004.
 Termination Notes
The Desktop Storage Pack requires external termination.
The SPARCstorage UniPack does not require external termination.
The Upper LED indicates termination of SCSI Data Bits D15 - D8.
The Lower LED indicates termination of SCSI Data Bits D7 - D0. 
 Reference
SPARCstorage UniPack Hardware Setup Instructions, 802-3227.
 
 |