 SCSI (SSHA)
 
| Workstations: | Sun 4/15, 4/30, 4/40, 4/50, 4/60, 4/65, 4/75 SPARCstation 4, 5, 10, 20
 Ultra 1, 1E, 2
 |  Option 1055
| 501-1759 | 501-1850 |  
| FCC-A/VCCI-1 15/30/40/50/60/65/75
 | FCC-B/VCCI-2 15/30/40/50/60/65/75
 SS4/SS5/SS10/SS20
 U1/U1E/U2
 |   
 Power
0.6 Amps @ +5Vdc
3.0 Watts
 Notes
The Sun-4/60 CPU requires Boot PROM 1.3 Version 3.
This card is not compatible with Slot-3 of the Sun-4/60/65.
Disable the SS10 onboard Ethernet if two or more SCSI host adapters
    are installed. Use an SBE/S or FSBE/S for Ethernet.
FCode on SSHA 501-1759 is not compatible with the SS10, SS20, Ultra 1/1E,
    and Ultra 2. The 501-1759 was discontinued in March 1991.
The SS4, SS5, SS10, SS20, Ultra 1/1E and Ultra 2 require 501-1850-02.
    Refer to BugID 1264704.
Add the following to /etc/system on Solaris 2.6:
  forceload: drv/dma Refer to BugID 4078972.
 Reference 
 SBus SCSI Host Adapter Installation Guide for SPARCstations,
     800-5385. 
 |