 Differential Fast/Wide SCSI (DWIS/S)
 
| Workstations: | SPARCstation 5, 10, 20 Ultra 1, 1E, 2
 |  
| Servers: | SPARCserver 6x0MP, 1000, SPARCcenter 2000 Enterprise 3x00, 4x00, 5x00, 6x00, 10000
 |  
| Tape Libraries: | StorEdge L9, L20/L40/L60, L1000, L3500 |  Option 1062
| 370-1704 |  
| QLogic SP1710401 |  
  Notes
The minimum operating system is Solaris 2.3.
The DWIS/S supports up to 15 targets on the SCSI bus.
Do NOT mix narrow (8-bit) and wide (16-bit) SCSI devices on the same
    controller under Solaris 2.3. Install Patch 101378-01.
Warning messages are displayed if fast/wide SCSI is enabled under Solaris
    2.3. Install Patch 101378-01.
Set scsi_options=0x3f8 in /etc/system to enable
    fast/wide transfers.
The 2.1GB Disk Drive requires 0420 Firmware (370-1412-03) for optimal
    performance. Set scsi_options=0xf8 in the /etc/system
    file if older disk drive firmware is used. 
Install SunSwift in Slot 0 and DWIS/S in Slot 1 when installing SunSwift
    and DWIS/S on an E10000 I/O board. Refer to BugIDs 4046986, 4049704, and
    4091053.
 Reference
 SBus Intelligent SCSI Host Adapter, 801-5355. 
 |