Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



5.0GB 8 mm Tape Drive

Servers: SPARCserver 6x0MP, SPARCcenter 2000

Options 811 / 812 / 814 / 816

370-1415 370-1416
Exabyte EXB-8500
Black Bezel
Exabyte EXB-8500
Light Grey Bezel

Rear View

Address Select Switch Cable
In the Multi-Tape Backup Tray, Desktop Storage Module,
and SC2000, orient the Address Select Switch Cable as shown,
and plug it into P3.

Manual Eject Switch

Power

2.0 Amps @ +5Vdc
0.7 Amps @ +12Vdc
18.4 Watts

Jumper Settings

Jumper P3
SCSI ID 1-2 3-4 5-6
4 In Out Out
5 In Out In
3 Out In In
2 Out In Out
1 Out Out In
0 Out Out Out

Switch U2
SCSI ID 1 2 3
4 Off Off On
5 On Off On
3 On On Off
2 Off On Off
1 On Off Off
0 Off Off Off

Notes

  1. The minimum operating system is SunOS 4.1.2.
  2. Use 54000 as the d(bpi), argument to the dump command in the high-density 8500 compatibility mode.
  3. Use 13000 as the s(size), argument to the dump command in the high-density 8500 compatibility mode.
  4. Use 6000 as the s(size), argument to the dump command in the low-density 8200 compatibility mode.
  5. The 112 Meter Tape part number is 370-1298-01.
  6. The Cleaning Kit part number is 370-2344-01.

References

  1. 5.0 Gbyte 8mm Tape Drive Installation Manual, 800-7008.
  2. Product Note 5.0 Gbyte 8mm Tape Drive, 800-7303.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback