2.3GB 8 mm Tape Drive
Servers: |
SPARCserver 6x0MP |
Options 566 / 802 / 804
370-1297 |
370-1405 |
Exabyte EXB-8200 Black Bezel |
Exabyte EXB-8200 Light Grey Bezel |
Rear View |
|
|
Jumper P2 |
SCSI ID |
(MSB) 1 |
2 |
(LSB) 3 |
4 |
In |
Out |
Out |
5 |
In |
Out |
In |
3 |
Out |
In |
In |
2 |
Out |
In |
Out |
1 |
Out |
Out |
In |
0 |
Out |
Out |
Out |
|
Address Select Switch Cable
|
In the Desktop Storage Module and External Storage Module, orient
the Address Select Switch Cable as shown, and plug it into P2.
|
Power
- 4.0 Amps @ +5Vdc
- 1.2 Amps @ +12Vdc
- 34.4 Watts
MX Card |
|
|
Dip Switch U32 |
SWITCH |
SETTING |
DESCRIPTION |
1 |
On |
Bypass memory test |
2 |
On |
Enable parity checking |
3 |
On |
Even byte disconnect |
4 |
Off |
Report busy status |
5 |
On |
Variable block mode on power up |
6 |
Off |
No disconnect during data transfer |
7 |
Off |
Not used |
8 |
Off |
P6 cartridge type |
|
|
Manual Eject Switch |
|
Notes
- The 112 Meter Tape part number is 370-1298-01.
- The Cleaning Kit part number is 370-2344-01.
-
ECO WO_01575 enabled Parity checking on the MX card.
Parity checking is disabled on drives shipped prior to December 1991.
Reference
- Sun 2.3-Gbyte 8mm Tape Drive Configuration Procedures for 56-Inch
Data Center Cabinets, 813-2081.
|