20-40GB 8 mm Tape Drive
Servers: |
Enterprise 3x00, 4x00, 5500, 6500 |
Options 6225 / 6226 / 6230 / 6231 / 6232
6233 / 6234 / 6235 / 6236 / 6237 / 6238
TAP8MM-011A / TAP8MM-021A / TAP8MM-400G
LIB8MM1-400G / TAP8MMB-400G / TAP8MMC-400G
370-2183 |
370-2184 |
370-2401 |
EXB-8900 Single-Ended Light Grey Bezel
w LCD Display |
EXB-8900 Single-Ended Medium Grey Bezel
w/o LCD Display |
EXB-8900 Differential EXB-220 Bezel
w/o LCD Display |
Front View |
|
|
Rear View |
|
Power
- 1.6 Amps @ +5Vdc
- 0.6 Amps @ +12Vdc
- 15.2 Watts
Jumper Settings
Remote Address Connector |
LOCATION |
SETTING |
DESCRIPTION |
0 |
As required |
SCSI ID 0 (20) |
1 |
As required |
SCSI ID 1 (21) |
2 |
As required |
SCSI ID 2 (22) |
3 |
As required |
SCSI ID 3 (23) |
|
|
Drive Configuration Guidelines |
SCSI HOST ADAPTER |
COMPRESSION |
OTHER DEVICES ON THE BUS |
MAX # OF DRIVES PER HOST ADAPTER |
Fast/Wide |
Not Enabled |
No |
6 |
Fast/Wide |
Not Enabled |
Yes |
4 |
Narrow |
Not Enabled |
No |
3 |
Narrow |
Not Enabled |
Yes |
2 |
Narrow |
Enabled |
Yes or No |
1 |
Fast/Wide |
Enabled |
Yes or No |
1 |
|
|
Library Configuration Guidelines |
COMPRESSION |
MAX # OF LIBRARIES PER HOST ADAPTER |
Not Enabled |
3 |
Enabled |
2 |
|
Notes
- The minimum operating system is Solaris 2.5.
- The 170 Meter AME Tape part number is 370-2395-01.
- The Cleaning Kit part number is 370-2396-01.
- Firmware 37F Update Tape is part number 370-3367-01.
- Firmware 37F is not compatible with EXB-8900 370-xxxx-02 Rev 52.
- The E3000 requires internal SCSI Cable 530-2381.
- The E4000 requires internal SCSI Cable 530-2382.
- The E5000 does not provide adequate cooling for the EXB-8900.
- The E6000 does not provide adequate cooling for the EXB-8900.
References
-
20-40 Gbyte 8mm Tape Drive Installation and User's Guide,
802-7712.
-
20-40 Gbyte 8mm Tape Drive Installation Guide, 805-0416.
|