Servers: |
Sun Fire X2250, X4150, X4250, X4450 |
Telco: |
Netra X4250, X4450 |
Options 6380A / 6381A / 6382A / 6437A
371-3067 |
371-3068 |
371-3068 |
371-3069 |
DDR2-667/PC2-5300 2-Rank/512Mbit SDRAM
1.8V VDD/VDDQ
1GB Fully Buffered DIMM 2GB FRU 540-7346
2GB Option 6880A
|
DDR2-667/PC2-5300 2-Rank/512Mbit SDRAM
1.8V VDD/VDDQ
2GB Fully Buffered DIMM 4GB FRU 540-7347
4GB Option 6381A
|
DDR2-667/PC2-5300 2-Rank/1Gbit SDRAM
1.8V VDD/VDDQ
2GB Fully Buffered DIMM 4GB FRU 540-7347
4GB Option 6381A
|
DDR2-667/PC2-5300 2-Rank/512Mbit SDRAM
1.8V VDD/VDDQ
4GB Fully Buffered DIMM 8GB FRU 540-7348
8GB Option 6382A
|
371-4404 |
DDR2-667/PC2-5300 2-Rank/2GBit SDRAM
1.5V VDD/VDDQ
8GB Fully Buffered DIMM 16GB FRU 540-7820
16GB Option 6437A
Sun Fire X4450 only |
Netra X4250 Codename: Aries
Netra X4450 Codename: Argo
Sun Fire X2250 Codename: Venus
Sun Fire X4150 Codename: Doradi
Sun Fire X4250 Codename: Doradi 2U
Sun Fire X4450 Codename: Tucani |
Notes
- Install memory in matched pairs.
- Memory FRUs include two matched DIMMs.
- DIMMs are not labeled with the FRU part number.
- DIMMs are labeled with the manufacturing part number.
- 2GB Micron MT36HTF25672FY-667 is based on 512Mbit SDRAM.
- 2GB Qimonda HYS72T256520HFD-3S-B is based on 512Mbit SDRAM.
- 2GB Qimonda HYS72T256421EFA-3S-C is based on 1Gbit SDRAM.
- 2GB Qimonda HYS72T256421EFA-3S-C was added to the AVL in September 2008.
- Quantity and size of components are dependent on DIMM size
and manufacturer.
Sun Fire X2250 Notes
- Install the largest capacity memory in the lowest numbered slots.
- Install the pairs in slots A0/B0, C0/D0, A1/B1, and then C1/D1.
- Use DDR2-667 FBDIMMs with 1333MHz Front Side Bus processors only.
- The Xeon E5405, L5420, and X5460 FSB operates at 1333MHz.
- Use DDR2-800 FBDIMMs with 1600MHz Front Side Bus processors only.
- The Xeon E5462, E5472, and X5272 FSB operates at 1600MHz.
- Mixing DDR2-667 and DDR2-800 FBDIMMs on the system board is not supported.
Sun Fire X4150 and X4250 Notes
- Install the largest capacity memory in the lowest numbered slots.
- Install the first DIMM pair in slots A0/B0. Install the second pair in slots C0/D0.
- Install additional memory in slots A1/B1, C1/D1, A2/B2, C2/D2, A3/B3, and C3/D3.
- Qimonda HYS72T256421EFA-3S-C requires X4150 ELOM BIOS 1ADQW027.
- Qimonda HYS72T256421EFA-3S-C requires X4150/X4250 ILOM BIOS 1ADQW052.
Sun Fire X4450 Notes
- Install the largest capacity memory in the lowest numbered slots.
- Install Memory Filler 371-3651 in all unused slots.
- Install the first DIMM pair in slots A0/B0. Install the second pair in slots C0/D0.
- Install additional memory in slots A1/B1, C1/D1, A2/B2, C2/D2, A3/B3, C3/D3
A4/B4, C4/D4, A5/B5, C5/D5, A6/B6, C6/D6, A7/B7, and C7/D7.
- The Memory Mezzanine is not labeled with the FRU part number.
- A 3mm allen wrench is required to remove the Memory Riser cap-head screws.
- The X4450 requires BIOS 3B55 when Low Voltage 1.5V DIMMs are installed.
References
-
Sun Fire X2250 Installation Guide, 820-4591.
-
Sun Fire X2250 Service Manual, 820-4593.
-
Sun Fire X2250 Product Notes, 820-4594.
-
Sun Fire X4150 Server Installation Guide, 820-1851.
-
Sun Fire X4150 Server Service Manual, 820-1852.
-
Sun Fire X4150 Server Product Notes, 820-1854.
-
Sun Fire X4250 Product Notes, 820-4211.
-
Sun Fire X4250 Service Manual, 820-4214.
-
Sun Fire X4250 Installation Guide, 820-4217.
-
Sun Fire X4450 Server Product Notes, 820-2703.
-
Sun Fire X4450 Server Service Manual, 820-2707.
-
Sun Fire X4450 Server Installation Guide, 820-2709.
-
Netra X4250 Installation Guide, 820-4055.
-
Netra X4250 Service Manual, 820-4056.
-
Netra X4250 Product Notes, 820-4059.
-
Netra X4450 Installation Guide, 820-4015.
-
Netra X4450 Service Manual, 820-4017.
-