Sun Fire V60x / V65x
StorEdge 5210 NAS / 5310 NAS
Options 5122 / 5123 / 5124 / 5125
370-6038 |
370-6039 |
370-6040 |
DDR, PC2100, CL2, ECC 256MB Registered DIMM
512MB FRU F370-6038 512MB Option 5122
V60x/V65x |
DDR, PC2100, CL2, ECC 512MB Registered DIMM
512MB FRU F370-6039 1GB Option 5123
V60x/V65x |
DDR, PC2100, CL2, ECC 1GB Registered DIMM
1GB FRU F370-6040 2GB Option 5124
V60x/V65x/5210NAS/5310NAS |
370-6041 |
370-6141 |
370-7570 |
DDR, PC2100, CL2, ECC Single Bank 2-2-2 Latency
2GB Registered DIMM 4GB not shipped |
DDR, PC2100, CL2, ECC Double Bank 2-3-3 Latency
2GB Registered DIMM 4GB Option 5125 V65x only |
DDR, PC2700, CL2.5, ECC Single Bank 2.5-3-3 Latency
1GB Registered DIMM 1GB FRU F370-7570 No Option
5210NAS/5310NAS |
System Codenames
System |
Codename |
Sun Fire V60x |
Grizzly |
Sun Fire V65x |
Grizzly 2U |
StorEdge 5210 NAS |
Audi |
StorEdge 5310 NAS |
Mustang |
Notes
- Install memory in pairs, beginning with Bank 1, Slots 1A and 1B.
- When mixing sizes, install 256/512MB DIMMs in Bank 1 and
1/2GB DIMMs in Bank 2.
- DIMM failure LEDs are located between the DIMM sockets and CPU 1.
- An illuminated LED indicates a double-bit DIMM error.
256MB DIMM Notes
- Infineon 256MB DIMM 370-6038 was released in May 2003.
- Micron was added as a second source in March 2004.
- F370-6038-01 includes one 370-6038 256MB DIMM.
- F370-6038-02 includes two 370-6038 256MB DIMMs from the same vendor.
- Do Not mix Infineon and Micron DIMMs in the same bank.
2GB DIMM Notes
- 2GB DIMM 370-6041 was released in May 2003 and inactivated in January 2004.
- Option 5125 with 2GB DIMM 370-6041 was not shipped.
- 2GB DIMM 370-6141 was released in Jaunary 2004.
- F370-6141 includes two 370-6141 2GB DIMMs.
- 2GB DIMMs have not been tested with 256MB, 512MB, and 1GB DIMMs.
- Mixing 2GB DIMMs with 256MB, 512MB, and 1GB DIMMs is not supported.
References
-
Sun Fire V60x and V65x Server User Guide, 817-2023.
-
Sun Fire V60x and V65x Server Troubleshooting Guide, 817-2024.
-
Sun Fire V60x and V65x Server Management Guide, 817-2025.
-
Sun Fire V60x and V65x Server Release Notes, 817-2026.
-
Sun Fire V60x and V65x Server Memory Modules Removal and Replacement Instructions, 817-2284.
|