Sun Fire V20z / V40z
Options 9251 / 9252 / 9253 / 9266
370-6643 |
370-6644 |
370-6645 |
370-7063 |
DDR PC2700 CL2.5 ECC 512MB Registered DIMM
1GB FRU F370-6643 1GB Option 9251
V20z/V40z |
DDR PC2700 CL2.5 ECC 1GB Registered DIMM
2GB FRU F370-6644 2GB Option 9252
V20z/V40z |
DDR PC2700 CL2.5 ECC 2GB Registered DIMM
4GB FRU F370-6645 4GB Option 9253
V20z only |
DDR PC2700 CL2.5 ECC 2GB Registered DIMM
4GB FRU F370-7063 4GB Option 9266
V40z only |
Sun Fire V20z Codename: Stinger2P
Sun Fire V40z Codename: Stinger4P |
Notes
- Memory FRUs and Memory Options include two DIMMs.
- The Memory Controller is integrated in the Opteron processor.
- Mixing DDR333/PC2700 and DDR400/PC3200 DIMMs is not supported.
Installation Notes
- The minimum Opteron requirement is one CPU0 DIMM (not supported by Sun).
- Single DIMM Sun Fire V20z and V40z configurations are not supported.
The minimum requirement is one memory option (two DIMMs) in each CPU
(including V40z daughterboards).
- Install memory in pairs, beginning with CPU 0 DIMM 0 and DIMM 1.
- Two DIMMs of the same memory size, speed, and manufacturer form a pair.
- CPU 0 and CPU 1 Memory pairs are Bank 0, DIMM 0/DIMM 1 and
Bank 1, DIMM 2/DIMM 3 for each CPU.
- Only CPU 0 DIMMs (Banks 0 and 1 adjacent to CPU 0) are accessible
in a single CPU system (CPU 0).
- Memory is mapped globally and is accessible by either CPU in a
dual CPU system.
- The minimum daughterboard memory requirement is two DIMMs per processor.
Voltage Regulator Module Notes
- Opteron C0 and CG Stepping CPU Options include Memory
Voltage Regulator Module (VRM) 370-6646.
- Opteron E0 Stepping CPU Options include Memory VRM 370-7747.
- CPU0 Memory Voltage Regulator Module is required
when CPU0 memory is installed.
- CPU1 Memory Voltage Regulator Module is required
when CPU1 memory is installed.
References
-
Sun Fire V20z and V40z Servers Installation Guide, 817-5246.
-
Sun Fire V20z and V40z Servers User Guide, 817-5248.
-
Sun Fire V20z and V40z Servers Management Guide, 817-5249.
-
Sun Fire V20z and V40z Servers Release Notes, 819-1771.
-
Sun Fire V20z and V40z Servers Troubleshooting Techniques and Diagnostics Guide, 817-7184.
Sun Fire V20z / V40z
Options 7299 / 9295 / 9296 / 9297
370-7804 |
370-7805 |
370-7806 |
DDR PC3200 ECC 512MB Registered DIMM
1GB FRU F540-6427 1GB Option 9295
V20z/V40z |
DDR PC3200 ECC 1GB Registered DIMM
2GB FRU F540-6428 2GB Option 9296
V20z/V40z |
DDR PC3200 ECC 2GB Registered DIMM
4GB FRU F540-6429 4GB Option 9297
V20z/V40z |
371-1457 |
371-1458 |
371-1459 |
371-1460 |
DDR PC3200 ECC 512MB Registered DIMM
1GB FRU F540-6835 1GB Option 9295A-Z
V20z Khepri 2.5 V40z Sobek 2 V40Z Sobek 3 |
DDR PC3200 ECC 1GB Registered DIMM
2GB FRU F540-6836 2GB Option 9296A-Z
V20z Khepri 2.5 V40z Sobek 2 V40Z Sobek 3 |
DDR PC3200 ECC 2GB Registered DIMM
4GB FRU F540-6837 4GB Option 9297A-Z
V20z Khepri 2.5 V40z Sobek 2 V40Z Sobek 3 |
DDR PC3200 ECC 4GB Registered DIMM
8GB FRU F540-6838 8GB Option 7299A-Z
V40z Sobek 2 V40Z Sobek 3 |
Sun Fire V20z Codename: Stinger2P
Sun Fire V40z Codename: Stinger4P |
Notes
- Memory FRUs and Memory Options include two DIMMs.
- The Memory Controller is integrated in the Opteron processor.
- Mixing DDR333/PC2700 and DDR400/PC3200 DIMMs is not supported.
- DDR400/PC3200 DIMMs are not supported with Opteron C0 or CG Stepping.
Installation Notes
- The minimum Opteron requirement is one CPU0 DIMM (not supported by Sun).
- Single DIMM Sun Fire V20z and V40z configurations are not supported.
The minimum requirement is one memory option (two DIMMs) in each CPU
(including V40z daughterboards).
- Install memory in pairs, beginning with CPU 0 DIMM 0 and DIMM 1.
- Two DIMMs of the same memory size, speed, and manufacturer form a pair.
- CPU0 and CPU1 Memory pairs are Bank 0, DIMM 0/DIMM 1 and Bank 1,
DIMM 2/DIMM 3 for each CPU.
- Only CPU 0 DIMMs (Banks 0 and 1 adjacent to CPU 0) are accessible
in a single CPU system (CPU 0).
- Memory is mapped globally and is accessible by either CPU in a
dual CPU system.
DDR400/PC3200 BIOS Restrictions
- V20z BIOS <1.33.5.2 and V40z BIOS <2.32.8.2
- The maximum addressable memory per CPU is 6GB.
- Only two 2GB DIMMS per CPU are supported.
- Install 2GB DIMMS in DIMM 0 and DIMM 1, then install 1GB or 512GB DIMMs.
- These restrictions are resolved in V20z BIOS 1.33.5.2 (NSV 2.3.0.11a).
- These restrictions are resolved in V40z BIOS 2.32.8.2 (NSV 2.3.0.6h).
Voltage Regulator Module Notes
- Opteron C0 and CG Stepping CPU Options include Memory
Voltage Regulator Module (VRM) 370-6646.
- Opteron E0 Stepping CPU Options include Memory VRM 370-7747.
- CPU0 Memory Voltage Regulator Module is required
when CPU0 memory is installed.
- CPU1 Memory Voltage Regulator Module is required
when CPU1 memory is installed.
References
-
Sun Fire V20z and V40z Servers Installation Guide, 817-5246.
-
Sun Fire V20z and V40z Servers User Guide, 817-5248.
-
Sun Fire V20z and V40z Servers Management Guide, 817-5249.
-
Sun Fire V20z and V40z Servers Release Notes, 819-1771.
-
Sun Fire V20z and V40z Servers Troubleshooting Techniques and Diagnostics Guide, 817-7184.
|