SPARCstation 4 / SPARCstation 5
Options 108 / 132
501-2470 |
501-2471 |
8MB 5.0V ECC 1Mx72 Fast Page
60ns DIMM Option 108 |
32MB 5.0V ECC 4Mx66 Fast Page
60ns DIMM Option 132 |
Memory Map
SS4 SOCKET |
SS5 SOCKET |
DIMM |
ADDRESS RANGE |
None |
J0403 |
DIMM 7 |
0e000000 - 0fffffff |
None |
J0402 |
DIMM 6 |
0c000000 - 0dffffff |
None |
J0401 |
DIMM 5 |
0a000000 - 0bffffff |
J0305 |
J0400 |
DIMM 4 |
08000000 - 09ffffff |
J0304 |
J0303 |
DIMM 3 |
06000000 - 07ffffff |
J0303 |
J0302 |
DIMM 2 |
04000000 - 05ffffff |
J0302 |
J0301 |
DIMM 1 |
02000000 - 03ffffff |
J0301 |
J0300 |
DIMM 0 |
00000000 - 01ffffff |
Notes
- Install the highest capacity DIMM in Slot 0 under Solaris 1.x.
- The minimum memory requirement is one DIMM in Bank 0.
- The SS4 and SS5 use a 66-bit parity protected memory subsystem.
- If a memory error occurs and the DIMM location is not reported,
use the MFAR (memory fault address register) value as the physical
address of the memory error.
References
-
SPARCstation 4 Service Manual, 802-1529.
-
SPARCstation 5 Service Manual, 801-6396.
|