Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



Servers: SPARC Enterprise T5120, T5140, T5220, T5240, T5440
Sun Blade T6320
Telco: Netra T5220, T5440

Options: X4200A / X4203A / X4204A
X4200AF / X4203AF / X4290AF
SESX2A1Z / SESX2B1Z / SESX2C1Z / SESX2D1Z
SESX2A2Z / SESX2B2Z
SEVX1CB1Z / SEVX1CC1Z / SEVX1CD1Z
SEVX1DB1Z / SEVX1DC1Z / SEVX1DD1Z
SEVX1EB1Z / SEVX1EC1Z / SEVX1ED1Z / SEVX1EC2Z

501-7952 501-7953 501-7954
371-2142
DDR2-667/PC2-5300
2-Rank/512Mbit SDRAM
1.8V VDD/VDDQ
1GB Fully Buffered DIMM
1GB FRU 501-7952
2GB Option X4200A
2GB Option SESX2A1Z
371-2143
DDR2-667/PC2-5300
2-Rank/512Mbit SDRAM
1.8V VDD/VDDQ
2GB Fully Buffered DIMM
2GB FRU 501-7953
4GB Option X4203A
4GB Option SESX2B1Z
371-2145
DDR2-667/PC2-5300
2-Rank/1Gbit SDRAM
1.8V VDD/VDDQ
4GB Fully Buffered DIMM
4GB FRU 501-7954
8GB Option X4204
8GB Option SESX2C1Z
16GB Option SEVX1EC1Z
32GB Option SEVX1CC1Z
32GB Option SEVX1DC1Z
511-1161 511-1262 511-1264 511-1408
371-2144
DDR2-667/PC2-5300
2-Rank/1Gbit SDRAM
1.8V VDD/VDDQ
2GB Fully Buffered DIMM
2GB FRU 511-1161
4GB Option X4203AF
4GB Option SESX2B2Z
8GB Option SEVX1CB1Z
8GB Option SEVX1DB1Z
8GB Option SEVX1EB1Z
371-2146
DDR2-667/PC2-5300
2-Rank/1Gbit SDRAM
1.8V VDD/VDDQ
8GB Fully Buffered DIMM
8GB FRU 511-1262
16GB Option X4290AF
16GB Option SESX2D1Z
16GB Option SEVX1CD1Z
16GB Option SEVX1DD1Z
32GB Option SEVX1ED1Z
371-4070
DDR2-667/PC2-5300
1-Rank/1Gbit SDRAM
1.8V VDD/VDDQ
1GB Fully Buffered DIMM
1GB FRU 511-1264
2GB Option X4200AF
2GB Option SESX2A2Z
371-4597
DDR2-800/PC2-6400
2-Rank/1Gbit SDRAM
1.8V VDD/VDDQ
4GB Fully Buffered DIMM
4GB FRU 511-1408
8GB Option SESX2C4Z
16GB Option SEVX1EC2Z

Netra T5220 Codename: Turgo
Netra T5440 Codename: Congo
SPARC Enterprise T5120 Codename: Huron 1U
SPARC Enterprise T5220 Codename: Huron 2U
SPARC Enterprise T5140 Codename: Maramba 1U
SPARC Enterprise T5240 Codename: Maramba 2U
SPARC Enterprise T5440 Codename: Batoka
Sun Blade T6320 Codename: Glendale

T5120/T5220/T6320 Notes

  1. Quantity and size of components are dependent on DIMM size and manufacturer.
  2. Four, eight, and sixteen FBDIMM configurations are supported.
  3. All FBDIMMs in a Branch must have the same Sun part number.
  4. All FBDIMMs in the server must be the same capacity (i.e. all 1GB, all 2GB, all 4GB, or if supported, all 8GB).
  5. The minimum requirement is four FBDIMMs in the Channel 0, DIMM 0 slots.

T5140/T5240 Notes

  1. Eight, twelve, and sixteen FBDIMM configurations are supported on the system board.
  2. Eight and sixteen FBDIMM configurations are supported on the memory mezzanine.
  3. The system board requires sixteen FBDIMMs before installing the memory mezzanine.
  4. All FBDIMMs within a CMP must have the same memory size.
  5. If Firmware is < 7.1.7.f, all FBDIMMs must have the same memory size.
  6. Different size FBDIMMs on different CMPs are supported
    (i.e. FBDIMMs in CMP0 can have different memory size than those in CMP1)
    with Firmware 7.1.7.f and Firmware 7.2.2.e, but
    BugID 6879970 affects mixed memory configurations with Firmware 7.2.2.e,
  7. Firmware 7.2.6 (Patch 139444-06) fixes BugID 6879970.
  8. FBDIMMs within a Branch must have the same Sun part number.
  9. Mixing 1.8V and 1.5V FBDIMMs is not supported.
  10. Low Voltage 1.5V FBDIMMs require System Firmware 7.1.6.d.

Netra T5440 Notes

  1. All FBDIMMs must have the same memory size.
  2. FBDIMMs within a Branch must have the same Sun part number.
  3. Mixing 1.8V and 1.5V FBDIMMs is not supported.
  4. Low Voltage 1.5V FBDIMMs require System Firmware 7.1.6.d.
  5. Memory Riser 501-7678 is only compatible with 1.8V VDD/VDDQ DIMMs.
  6. Memory Riser 511-1231 is compatible with 1.5V and 1.8V VDD/VDDQ DIMMs.

SPARC Enterprise T5440 Notes

  1. All FBDIMMs within a single CPU/Memory module must have the same memory size.
  2. FBDIMMs on different CPU/Memory modules can be of different sizes.
  3. FBDIMMs within a Branch must have the same Sun part number.
  4. 4GB 800MHz FBDIMMs are only available on 1.6GHz systems, and cannot be mixed with FBDIMMs of other speeds.
  5. Install the first four FBDIMMs on the CPU/Memory Module.
  6. Install the next four FBDIMMs on the Memory Module in the D1 slots.
  7. Install the next eight FBDIMMs on the Memory Module in the D2 and D3 slots.

References

  1. Netra T5220 Installation Guide, 820-3009.
  2. Netra T5220 Service Manual, 820-3012.
  3. Netra T5220 Product Notes, 820-3014.
  4. Netra T5440 Installation Manual, 820-4442.
  5. Netra T5440 Service Manual, 820-4445.
  6. Netra T5440 Product Notes, 820-4447.
  7. SPARC Enterprise T5120 and T5220 Servers Product Notes, 820-2176.
  8. SPARC Enterprise T5120 and T5220 Servers Installation Guide, 820-2178.
  9. SPARC Enterprise T5120 and T5220 Servers Service Manual, 820-2181.
  10. SPARC Enterprise T5140 and T5240 Servers Product Notes, 820-3312.
  11. SPARC Enterprise T5140 and T5240 Servers Installation Guide, 820-3315.
  12. SPARC Enterprise T5140 and T5240 Servers Service Manual, 820-3318.
  13. SPARC Enterprise T5440 Server Product Notes, 820-3799.
  14. SPARC Enterprise T5440 Server Installation and Setup Guide, 820-3800.
  15. SPARC Enterprise T5440 Server Service Manual, 820-3801.
  16. Sun Blade T6320 Product Notes, 820-2383.
  17. Sun Blade T6320 Installation Guide, 820-2384.
  18. Sun Blade T6320 Service Manual, 820-2386.



Servers: SPARC Enterprise T5140, T5240
Sun Blade T6340
Telco: Netra T5440, T6340

Options T6340-X-21 / T6340-X-22 / T6340-X-24 / T6340-X-28
Options SESX2A3Z / SESX2B3Z / SESX2C3Z / SESX2D3Z

511-1150 511-1151 511-1152 511-1228
371-4138
DDR2-667/PC2-5300
1-Rank/1Gbit SDRAM
1.5V VDD/VDDQ
1GB Fully Buffered DIMM
1GB FRU 511-1150
2GB Option T6340-X-21
2GB Option SESX2A3Z


not supported
on Netra T5440
371-4139
DDR2-667/PC2-5300
2-Rank/1Gbit SDRAM
1.5V VDD/VDDQ
2GB Fully Buffered DIMM
2GB FRU 511-1151
4GB Option T6340-X-22
4GB Option SESX2B3Z
371-4140
DDR2-667/PC2-5300
2-Rank/1Gbit SDRAM
1.5V VDD/VDDQ
4GB Fully Buffered DIMM
4GB FRU 511-1152
8GB Option T6340-X-24
8GB Option SESX2C3Z
371-4141
DDR2-667/PC2-5300
2-Rank/2Gbit SDRAM
1.5V VDD/VDDQ
8GB Fully Buffered DIMM
8GB FRU 511-1228
16GB Option T6340-X-28
16GB Option SESX2D3Z

Netra T5440 Codename: Congo
Netra T6340 Codename: Scottsdale-LP
SPARC Enterprise T5140 Codename: Maramba 1U
SPARC Enterprise T5240 Codename: Maramba 2U
Sun Blade T6340 Codename: Scottsdale

T5140/T5240 Notes

  1. Eight, twelve, and sixteen FBDIMM configurations are supported on the system board.
  2. Eight and sixteen FBDIMM configurations are supported on the memory mezzanine.
  3. The system board requires sixteen FBDIMMs before installing the memory mezzanine.
  4. All FBDIMMs within a CMP must have the same memory size.
  5. If Firmware is < 7.1.7.f, all FBDIMMs must have the same memory size.
  6. Different size FBDIMMs on different CMPs are supported
    (i.e. FBDIMMs in CMP0 can have different memory size than those in CMP1)
    with Firmware 7.1.7.f and Firmware 7.2.2.e, but
    BugID 6879970 affects mixed memory configurations with Firmware 7.2.2.e,
  7. Firmware 7.2.6 (Patch 139444-06) fixes BugID 6879970.
  8. FBDIMMs within a Branch must have the same Sun part number.
  9. Mixing 1.8V and 1.5V FBDIMMs is not supported.
  10. Low Voltage 1.5V FBDIMMs require System Firmware 7.1.6.d.

Netra T5440 Notes

  1. All FBDIMMs must have the same memory size.
  2. FBDIMMs within a Branch must have the same Sun part number.
  3. Mixing 1.8V and 1.5V FBDIMMs is not supported.
  4. Low Voltage 1.5V FBDIMMs require System Firmware 7.1.6.g.
  5. Memory Riser 501-7678 is only compatible with 1.8V VDD/VDDQ DIMMs.
  6. Memory Riser 511-1231 is compatible with 1.5V and 1.8V VDD/VDDQ DIMMs.

References

  1. SPARC Enterprise T5140 and T5240 Servers Product Notes, 820-3312.
  2. SPARC Enterprise T5140 and T5240 Servers Installation Guide, 820-3315.
  3. SPARC Enterprise T5140 and T5240 Servers Service Manual, 820-3318.
  4. Sun Blade T6340 Server Module Installation and Administration Guide, 820-3900.
  5. Sun Blade T6340 Server Module Product Notes, 820-3901.
  6. Sun Blade T6340 Server Module Service Manual, 820-3902.
  7. Sun Netra T6340 Server Module Service Manual, 821-0902.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback