Servers: |
SPARC Enterprise T5120, T5140, T5220, T5240, T5440
Sun Blade T6320 |
Telco: |
Netra T5220, T5440 |
Options: X4200A / X4203A / X4204A
X4200AF / X4203AF / X4290AF
SESX2A1Z / SESX2B1Z / SESX2C1Z / SESX2D1Z
SESX2A2Z / SESX2B2Z
SEVX1CB1Z / SEVX1CC1Z / SEVX1CD1Z
SEVX1DB1Z / SEVX1DC1Z / SEVX1DD1Z
SEVX1EB1Z / SEVX1EC1Z / SEVX1ED1Z / SEVX1EC2Z
501-7952 |
501-7953 |
501-7954 |
371-2142 DDR2-667/PC2-5300 2-Rank/512Mbit SDRAM
1.8V VDD/VDDQ 1GB Fully Buffered DIMM 1GB FRU 501-7952
2GB Option X4200A 2GB Option SESX2A1Z
|
371-2143 DDR2-667/PC2-5300 2-Rank/512Mbit SDRAM
1.8V VDD/VDDQ 2GB Fully Buffered DIMM 2GB FRU 501-7953
4GB Option X4203A 4GB Option SESX2B1Z
|
371-2145 DDR2-667/PC2-5300 2-Rank/1Gbit SDRAM
1.8V VDD/VDDQ 4GB Fully Buffered DIMM 4GB FRU 501-7954
8GB Option X4204 8GB Option SESX2C1Z 16GB Option SEVX1EC1Z
32GB Option SEVX1CC1Z 32GB Option SEVX1DC1Z
|
511-1161 |
511-1262 |
511-1264 |
511-1408 |
371-2144 DDR2-667/PC2-5300 2-Rank/1Gbit SDRAM
1.8V VDD/VDDQ 2GB Fully Buffered DIMM 2GB FRU 511-1161
4GB Option X4203AF 4GB Option SESX2B2Z
8GB Option SEVX1CB1Z 8GB Option SEVX1DB1Z
8GB Option SEVX1EB1Z
|
371-2146 DDR2-667/PC2-5300 2-Rank/1Gbit SDRAM
1.8V VDD/VDDQ 8GB Fully Buffered DIMM 8GB FRU 511-1262
16GB Option X4290AF 16GB Option SESX2D1Z
16GB Option SEVX1CD1Z 16GB Option SEVX1DD1Z
32GB Option SEVX1ED1Z
|
371-4070 DDR2-667/PC2-5300 1-Rank/1Gbit SDRAM
1.8V VDD/VDDQ 1GB Fully Buffered DIMM 1GB FRU 511-1264
2GB Option X4200AF 2GB Option SESX2A2Z
|
371-4597 DDR2-800/PC2-6400 2-Rank/1Gbit SDRAM
1.8V VDD/VDDQ 4GB Fully Buffered DIMM 4GB FRU 511-1408
8GB Option SESX2C4Z 16GB Option SEVX1EC2Z
|
Netra T5220 Codename: Turgo
Netra T5440 Codename: Congo
SPARC Enterprise T5120 Codename: Huron 1U
SPARC Enterprise T5220 Codename: Huron 2U
SPARC Enterprise T5140 Codename: Maramba 1U
SPARC Enterprise T5240 Codename: Maramba 2U
SPARC Enterprise T5440 Codename: Batoka
Sun Blade T6320 Codename: Glendale
|
T5120/T5220/T6320 Notes
- Quantity and size of components are dependent on DIMM size and
manufacturer.
- Four, eight, and sixteen FBDIMM configurations are supported.
- All FBDIMMs in a Branch must have the same Sun part number.
- All FBDIMMs in the server must be the same capacity
(i.e. all 1GB, all 2GB, all 4GB, or if supported, all 8GB).
- The minimum requirement is four FBDIMMs in the Channel 0, DIMM 0 slots.
T5140/T5240 Notes
- Eight, twelve, and sixteen FBDIMM configurations are supported on the
system board.
- Eight and sixteen FBDIMM configurations are supported on the
memory mezzanine.
- The system board requires sixteen FBDIMMs before installing the
memory mezzanine.
- All FBDIMMs within a CMP must have the same memory size.
- If Firmware is < 7.1.7.f, all FBDIMMs must have the same memory size.
- Different size FBDIMMs on different CMPs are supported
(i.e. FBDIMMs in CMP0 can have different memory size than those in CMP1)
with Firmware 7.1.7.f and Firmware 7.2.2.e, but
BugID 6879970 affects mixed memory configurations with Firmware 7.2.2.e,
- Firmware 7.2.6 (Patch
139444-06)
fixes BugID 6879970.
- FBDIMMs within a Branch must have the same Sun part number.
- Mixing 1.8V and 1.5V FBDIMMs is not supported.
- Low Voltage 1.5V FBDIMMs require System Firmware 7.1.6.d.
Netra T5440 Notes
- All FBDIMMs must have the same memory size.
- FBDIMMs within a Branch must have the same Sun part number.
- Mixing 1.8V and 1.5V FBDIMMs is not supported.
- Low Voltage 1.5V FBDIMMs require System Firmware 7.1.6.d.
- Memory Riser 501-7678 is only compatible with 1.8V VDD/VDDQ DIMMs.
- Memory Riser 511-1231 is compatible with 1.5V and 1.8V VDD/VDDQ DIMMs.
SPARC Enterprise T5440 Notes
- All FBDIMMs within a single CPU/Memory module must have the same memory size.
- FBDIMMs on different CPU/Memory modules can be of different sizes.
- FBDIMMs within a Branch must have the same Sun part number.
- 4GB 800MHz FBDIMMs are only available on 1.6GHz systems, and
cannot be mixed with FBDIMMs of other speeds.
- Install the first four FBDIMMs on the CPU/Memory Module.
- Install the next four FBDIMMs on the Memory Module in the D1 slots.
- Install the next eight FBDIMMs on the Memory Module in the D2 and D3 slots.
References
-
Netra T5220 Installation Guide, 820-3009.
-
Netra T5220 Service Manual, 820-3012.
-
Netra T5220 Product Notes, 820-3014.
-
Netra T5440 Installation Manual, 820-4442.
-
Netra T5440 Service Manual, 820-4445.
-
Netra T5440 Product Notes, 820-4447.
-
SPARC Enterprise T5120 and T5220 Servers Product Notes, 820-2176.
-
SPARC Enterprise T5120 and T5220 Servers Installation Guide, 820-2178.
-
SPARC Enterprise T5120 and T5220 Servers Service Manual, 820-2181.
-
SPARC Enterprise T5140 and T5240 Servers Product Notes, 820-3312.
-
SPARC Enterprise T5140 and T5240 Servers Installation Guide, 820-3315.
-
SPARC Enterprise T5140 and T5240 Servers Service Manual, 820-3318.
-
SPARC Enterprise T5440 Server Product Notes, 820-3799.
-
SPARC Enterprise T5440 Server Installation and Setup Guide, 820-3800.
-
SPARC Enterprise T5440 Server Service Manual, 820-3801.
-
Sun Blade T6320 Product Notes, 820-2383.
-
Sun Blade T6320 Installation Guide, 820-2384.
-
Sun Blade T6320 Service Manual, 820-2386.
Servers: |
SPARC Enterprise T5140, T5240
Sun Blade T6340 |
Telco: |
Netra T5440, T6340 |
Options T6340-X-21 / T6340-X-22 / T6340-X-24 / T6340-X-28
Options SESX2A3Z / SESX2B3Z / SESX2C3Z / SESX2D3Z
511-1150 |
511-1151 |
511-1152 |
511-1228 |
371-4138 DDR2-667/PC2-5300 1-Rank/1Gbit SDRAM
1.5V VDD/VDDQ 1GB Fully Buffered DIMM 1GB FRU 511-1150
2GB Option T6340-X-21 2GB Option SESX2A3Z
not supported on Netra T5440 |
371-4139 DDR2-667/PC2-5300 2-Rank/1Gbit SDRAM
1.5V VDD/VDDQ 2GB Fully Buffered DIMM 2GB FRU 511-1151
4GB Option T6340-X-22 4GB Option SESX2B3Z
|
371-4140 DDR2-667/PC2-5300 2-Rank/1Gbit SDRAM
1.5V VDD/VDDQ 4GB Fully Buffered DIMM 4GB FRU 511-1152
8GB Option T6340-X-24 8GB Option SESX2C3Z
|
371-4141 DDR2-667/PC2-5300 2-Rank/2Gbit SDRAM
1.5V VDD/VDDQ 8GB Fully Buffered DIMM 8GB FRU 511-1228
16GB Option T6340-X-28 16GB Option SESX2D3Z
|
Netra T5440 Codename: Congo
Netra T6340 Codename: Scottsdale-LP
SPARC Enterprise T5140 Codename: Maramba 1U
SPARC Enterprise T5240 Codename: Maramba 2U
Sun Blade T6340 Codename: Scottsdale
|
T5140/T5240 Notes
- Eight, twelve, and sixteen FBDIMM configurations are supported on the
system board.
- Eight and sixteen FBDIMM configurations are supported on the
memory mezzanine.
- The system board requires sixteen FBDIMMs before installing the
memory mezzanine.
- All FBDIMMs within a CMP must have the same memory size.
- If Firmware is < 7.1.7.f, all FBDIMMs must have the same memory size.
- Different size FBDIMMs on different CMPs are supported
(i.e. FBDIMMs in CMP0 can have different memory size than those in CMP1)
with Firmware 7.1.7.f and Firmware 7.2.2.e, but
BugID 6879970 affects mixed memory configurations with Firmware 7.2.2.e,
- Firmware 7.2.6 (Patch
139444-06)
fixes BugID 6879970.
- FBDIMMs within a Branch must have the same Sun part number.
- Mixing 1.8V and 1.5V FBDIMMs is not supported.
- Low Voltage 1.5V FBDIMMs require System Firmware 7.1.6.d.
Netra T5440 Notes
- All FBDIMMs must have the same memory size.
- FBDIMMs within a Branch must have the same Sun part number.
- Mixing 1.8V and 1.5V FBDIMMs is not supported.
- Low Voltage 1.5V FBDIMMs require System Firmware 7.1.6.g.
- Memory Riser 501-7678 is only compatible with 1.8V VDD/VDDQ DIMMs.
- Memory Riser 511-1231 is compatible with 1.5V and 1.8V VDD/VDDQ DIMMs.
References
-
SPARC Enterprise T5140 and T5240 Servers Product Notes, 820-3312.
-
SPARC Enterprise T5140 and T5240 Servers Installation Guide, 820-3315.
-
SPARC Enterprise T5140 and T5240 Servers Service Manual, 820-3318.
-
Sun Blade T6340 Server Module Installation and Administration Guide, 820-3900.
-
Sun Blade T6340 Server Module Product Notes, 820-3901.
-
Sun Blade T6340 Server Module Service Manual, 820-3902.
-
Sun Netra T6340 Server Module Service Manual, 821-0902.
|