Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



RSM Array 2000 / StorEdge A3000
StorEdge A3500 / StorEdge A3500FC

Option 7020

370-2438 370-2439
8MB MPU SIMM
No Option Number
32MB RPA SIMM
Option 7020

8MB MPU SIMM 370-2438

32MB RPA SIMM 370-2439

Notes

  1. The Main Processor Unit (MPU) SIMMs serve as processor memory.
  2. The RAID Parity Assist (RPA) SIMMs serve as cache memory.
  3. Install 501-2439 in SIMM-1 and SIMM-3 for RPA High Bank.
  4. Install 501-2439 in SIMM-2 and SIMM-4 for RPA Low Bank.
  5. Install 501-2438 in SIMM-5 and SIMM-6 for MPU DRAM.
  6. Memory failures are reported as a pair of two SIMMS.
  7. The 370-2438 or 370-2439 are not labeled with a Sun part number.

References

  1. RSM Array 2000 Controller Module Installation Guide, 802-7602.
  2. RSM Array 2000 Installation and System Manual, 802-7603.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback