Netra X1 / Sun Fire V100
Options 7090 / 7091 / 7092
370-4289 |
370-4237 |
370-4281 |
128MB 3.3V ECC PC133 SDRAM DIMM
X1/V100 Option 7090 |
256MB 3.3V ECC PC133 SDRAM DIMM
X1/V100 Option 7091 |
512MB 3.3V ECC PC133 SDRAM DIMM
V100 Only Option 7092 |
Address Generation Logic Memory Mapping
Identical Size DIMMs Example
Mixed Size DIMMs Example
Memory Notes
- The memory installation sequence is Slot 3, 2, 1, and 0.
- Each DIMM slot addresses 512MB with 400MB and 500MHz UltraSPARC IIe.
- Each DIMM slot addresses 1GB with 550MHz and 650MHz UltraSPARC IIi.
- When equal size DIMMs are installed, the lowest slot number is
mapped to the lowest address range.
- When mixed size DIMMs are installed, the slot number with the
largest size DIMM is mapped to the lowest address range.
- Memory bus speed is set by OBP during initialization and is a ratio
of the CPU clock frequency.
References
-
Netra X1 Server User's Guide, 806-5980.
-
Sun Fire V100 Server User's Guide, 816-2756.
|