Netra CP2000/CP2100 Memory

Servers: Sun Fire 12K, 15K, E20K, E25K
Telco: Netra CT 410/810

375-3024 375-3025 375-3026 375-3125 375-3114
256MB
Single Wide
MEM-256MB
512MB
Single Wide
MEM-512MB
1GB
Double Wide
MEM-1GB
1GB
Single Wide
MEM-1GBSW
2GB
Double Wide
MEM-2GB

Notes

  1. The minimum CP2000 and CP2100 memory is 256MB.
  2. The maximum CP2000 and CP2100 memory is 2GB.
  3. XPC2000-MEM-2GB is only supported in the CP2100 series.

Installation Notes

  1. The maximum number of stacked memory boards is two.
  2. Install double wide memory first, then single wide memory.
  3. Double wide memory requires four Turrets, part number 230-1852.
  4. One PIM/PMC slot is blocked when single wide memory is installed.
  5. Two PIM/PMC slots are blocked when double wide memory is installed.

References

  1. 256/512MB Memory Module Installation and Removal Guide, 816-0854.
  2. 1GB Memory Module Installation and Removal Guide, 816-2917.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.