32MB SBus NVRAM Board

Workstations: Ultra 2
Disk Arrays: StorEdge A5000, A5100, A5200

Option 1075

375-0012
Micro Memory MM-1360C
32MB ECC

Notes

  1. The minimum operating system is Solaris 2.5.1.
  2. Device drivers for the NVRAM Board are in Netra NFS 1.2.
  3. The 375-0012-02 fixes BugID 4085112.
  4. Use the nvadm -v command to display the board status bits.
    Battery 0x00 Normal operation
    Battery 0x01 Battery 1 has open fuse or is not enabled
    Battery 0x02 Battery 1 has low voltage
    Battery 0x04 Battery 2 has open fuse or is not enabled
    Battery 0x08 Battery 2 has low voltage
    Battery 0x10 Battery 3 has open fuse or is not enabled
    Battery 0x20 Battery 3 has low voltage
    Dirty Bit 0x00 No valid data is present (Cache Data LED if Off)
    Dirty Bit 0x01 Valid data is present and the cache is dirty (Cache Data LED is On)

Reference

Installation and Users Guide, 805-1378.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.