Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



Sun Quad FastEthernet 1.0 (SQFE/S)

Codename: Quattro

Workstations: SPARCstation 5, 10, 20
Ultra 1, 1E, 2
Servers: SPARCserver 6x0MP, 1000, SPARCcenter 2000
Enterprise 3x00, 4x00, 5x00, 6x00

Option 1042

501-4302

Notes

  1. The minimum OS is Solaris 2.4 and Quad FastEthernet 1.0.
  2. QFE/S 1.0 uses the SUNWhmed device driver.
  3. QFE/S is not compatible with Sun Trunking 1.0.
  4. The SS1000 and SC2000 require OBP 2.26.
  5. One CPU per port is recommended for maximum throughput.
  6. Two CPUs per QFE/S is recommended for >=200MHz systems.
  7. SQFE <= 501-4302-03 fails the Fcode checksum test and will not configure during boot if the E3000-E6000 is set to Diagnostic mode. Set Keywitch diagnostics Off, OBP diag-switch? false, and OBP diag-level min.
  8. Set the NVRAM variable local-mac-address? to true to enable the MAC addresses of the network interfaces on the Quad FastEthernet board.

Reference

Sun Quad FastEthernet Installation Guide, 805-0732.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.