Seagate ST43401ND (2.9GB)
5 1/4" 5400 RPM Differential Fast/Wide SCSI
Options 583 / 584 / 585 / 586
370-1695 |
3 1/4" Height 992004-005/6 Elite 3 |
Top View |
 |
|
End View |
 |
|
Notes
- The minimum operating system is Solaris 2.3.
- Solaris 2.3 requires Patch 101378-xx.
- The firmware on 370-1695-02 is level 0407.
References
Differential SCSI Disk Tray Service Manual, 800-7341.
- 2.9GByte Disk Drive Installation Manual, 801-2066.
Product Note, 801-6582.
5 1/4" 5400 RPM Differential Fast/Wide SCSI
CS6400 Peripheral Cabinet
370-2766 |
420-6113-001 |
3 1/4" Height 992004-001 Elite 3 |
BSD Part Number |
Top View |
 |
|
End View |
 |
|
Power
- 2.85 Amps @ +5Vdc
- 1.85 Amps @ +12Vdc
- 36.45 Watts
Notes
- The firmware on 370-2766-01 is level 0105 for Seagate 992004-001.
- The firmware on 370-2766-01 is level 2100 for Seagate 992004-003,
as configured by Cray. This new firmware level causes failures
on the CS6400. The disk must be replaced with either an older
370-2766 (with firmware level 0105) or with 370-1695 (level 0407).
Reformatting the disk and restoring the firmware back to 0105 is
also possible. See Bug ID 4418573 for full details.
|