Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



Seagate ST43401ND (2.9GB)

5 1/4" 5400 RPM Differential Fast/Wide SCSI

Options 583 / 584 / 585 / 586

370-1695
3 1/4" Height
992004-005/6
Elite 3
Top View

End View

Notes

  1. The minimum operating system is Solaris 2.3.
  2. Solaris 2.3 requires Patch 101378-xx.
  3. The firmware on 370-1695-02 is level 0407.

References

  1. Differential SCSI Disk Tray Service Manual, 800-7341.
  2. 2.9GByte Disk Drive Installation Manual, 801-2066.
  3. Product Note, 801-6582.

Seagate ST43401ND (2.9GB)

5 1/4" 5400 RPM Differential Fast/Wide SCSI

CS6400 Peripheral Cabinet

370-2766 420-6113-001
3 1/4" Height
992004-001
Elite 3
BSD Part Number
Top View

End View

Power

2.85 Amps @ +5Vdc
1.85 Amps @ +12Vdc
36.45 Watts

Notes

  1. The firmware on 370-2766-01 is level 0105 for Seagate 992004-001.
  2. The firmware on 370-2766-01 is level 2100 for Seagate 992004-003, as configured by Cray. This new firmware level causes failures on the CS6400. The disk must be replaced with either an older 370-2766 (with firmware level 0105) or with 370-1695 (level 0407). Reformatting the disk and restoring the firmware back to 0105 is also possible. See Bug ID 4418573 for full details.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback