Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



Hitachi HUS103073FL3800 (73.4GB)

3 1/2" 10000 RPM Low Voltage Differential Ultra-320 SCSI

Workstations: Sun Blade 2500
Servers: Sun Fire V120, V1280, V210, V240, V250, V440
Sun Fire E20K, E25K, E2900
Telco: Netra 120, 1280, CT 410/810
Disk Arrays: StorEdge A1000, D1000
StorEdge S1, D2, 3120, 3310, D240

Options 5245 / 5263 / 5264 / 5265 / 5886
Option XTA-3310-73GB-10K
Option XTA-SC1NC-73G10K
Option XRA-SC1CB-73G10K

390-0176
1" Height
Python-A
540-5456 540-5563 540-5771 540-6056
Spud Bracket FRU
w 1" Bracket 540-3024
3000 Series FRU
1" 3300 Bracket
XTA-3310-73GB-10K
CT 410/810 FRU
N120/N1280/V120 FRU
NEBS Level 3
w 1" Bracket 540-3024
w Plate 340-5928
or Plate 340-7269
3000 Series FRU
1" 3100 Bracket
XTA-SC1NC-73G10
02/06/04 - 10/26/05
540-5455 540-5652
StorEdge D240
Center FRU
Spud Bracket FRU
w 1" Bracket 540-3024
w Plate 340-5928
or Plate 340-7269
StorEdge D240
Left/Right FRU
Assembly 599-2652
or Assembly 540-5703
Drive 540-5456
w Bracket 340-6476

Notes

  1. Drive 390-0176 was released in June 2005. (WO_31257)
  2. The Sun Model Number on the serial number label is HUS10733ASUN72G.
  3. XTA-3310-73GB-10K changed from 540-5563 to 540-6448 in October 2006. (WO_34374)



Hitachi HUS103073FL3800 (73.4GB)

3 1/2" 10000 RPM Low Voltage Differential Ultra-320 SCSI

Workstations: Sun Blade 2500
Servers: Sun Fire V120, V1280, V125, V210, V240, V250, V440
Sun Fire E2900
Telco: Netra 120, 1280, CT 410/810
Disk Arrays: StorEdge A1000, D1000
StorEdge S1, D2, 3120, 3310, 3320, D240

Options 5127 / 5263 / 5264 / 5886 / 7205
Option XTA-3310-73GB-10K
Option XTA-SC1NC-73G10K
Option XRA-SC1CB-73G10K

390-0265
1" Height
Ultrastar 10K300
540-5456 540-5563 540-5771
Spud Bracket FRU
w 1" Bracket 540-3024
3000 Series FRU
1" Bracket
XTA-3310-73GB-10K
CT 410/810 FRU
N120/N1280/V120 FRU
NEBS Level 3
w 1" Bracket 540-3024
w Plate 340-5928
or Plate 340-7269
540-5937 540-6056 540-6448
V60x/V65x FRU
1" Bracket 330-3696
-04 = 390-0252
3000 Series FRU
1" 3100 Bracket
XTA-SC1NC-73G10
02/06/04 - 10/26/05
3000 Series FRU
1" Bracket

XTA-SC1NC-73G10K
(From 10/26/05)
XTA-3310-73GB-10K
540-6599 540-6600 540-6603
Spud Bracket FRU
1" Bracket 540-3024
Spud Bracket FRU
1" Bracket 540-3024
Plate 341-1986
NEBS Level 3
1" Bracket 540-3024
Plate 341-1986
540-5455 540-5652
StorEdge D240
Center FRU
Spud Bracket FRU
w 1" Bracket 540-3024
w Plate 340-5928
or Plate 340-7269
StorEdge D240
Left/Right FRU
Assembly 599-2652
or Assembly 540-5703
Drive 540-5456
w Bracket 340-6476

Notes

  1. Drive 390-0265 was released in October 2005. (WO_31849)
  2. The Sun Model Number on the serial number label is HUS10733ASUN72G.
  3. Assembly 540-6448 with 390-0265 was released in October 2005. (WO_31708)
  4. XTA-SC1NC-73G10K changed from 540-6056 to 540-6448 in October 2005. (WO_31505)
  5. Drive 390-0265 was added to 540-5455, 540-5456, 540-5563, 540-5771, 540-5937, and 540-6056 in November 2005. (WO_32024)
  6. Assemblies 540-6599, 540-6600, and 540-6603 with 390-0265 were released in December 2005. (WO_31926)
  7. Option 5264 changed from 540-5456 to 540-6599 in January 2006. (WO_32023)
  8. Option 5265 changed from 540-5771 to 540-6603 in January 2006. (WO_32023)
  9. XRA-SC1CB-73G10K changed from 540-5455 to 540-6600 in January 2006. (WO_32023)
  10. XTA-3310-73GB-10K changed from 540-5563 to 540-6448 in October 2006. (WO_34374)

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback