Fujitsu MAP3367NC (36.4GB)
3 1/2" 10000 RPM Low Voltage Differential Ultra-320 SCSI
46 Byte Inquiry (TEC485-2405331)
Go to 96 Byte Inquiry (TEC485-2405361)
Servers: |
Sun Fire V1280 |
Telco: |
Netra t1400/1405, 1280 |
Disk Arrays: |
StorEdge A1000, D1000
StorEdge MultiPack
StorEdge S1, D2, D240 |
Options 5242 / 5243 / 5250 / 5257 / 5261 / 5267 / 5884
390-0110 |
1" Height Allegro 8LE CA06200-B1xx
46 Byte Inquiry TEC485-2405331 |
540-4521 |
540-4904 |
540-5462 |
540-5693 |
Spud Bracket FRU w 1" Bracket 540-3024 |
Spud Bracket FRU
w 1" Bracket 540-3024
w Plate 340-5928
or Plate 340-7269
not qualified on V210/V240/V250 |
Spud Bracket FRU
w 1" Bracket 540-3024
<= Rev 53
use of 390-0110 was
discontinued May 2003
not V440 qualified
See V440 Notes below
|
Netra t1400/1405 FRU NEBS Level 3
w 1" Bracket 540-3024
added June 2003 |
540-4520 |
595-6394 |
StorEdge D240
Center FRU 12-Slot A1000/D1000 FRU
w 1" Bracket 540-3024
w Plate 340-4288 or 340-6640
or Plate 340-5928 or 340-7269 |
StorEdge D240
Left/Right Assembly Assembly 599-2593 or Assembly 540-5702
Drive 540-4521 w Bracket 340-6476 |
Notes
- Drive 390-0110 was released in March 2003.
(WO_26134)
- Drive 390-0110 was not tested in Ultra 60/80 or E250/450/220R/420R.
Netra t 1120/1125 Notes
- The Netra t 1120/1125 shipped with 540-4521 and 540-4919.
- 540-4919 replaced 540-4521 in the Netra t 1120/1125 in May 2001.
(WO_20687)
- Drive 390-0110 was added to Assembly 540-4521 in March 2003.
(WO_26134)
- Drive 390-0110 was not tested in the Netra t 1120/1125.
Netra ct 400/800 Notes
- The Netra ct 400/800 shipped with 540-4520 and 540-4689.
- 540-4689 replaced 540-4520 in the Netra ct 400/800 in April 2001.
(WO_20531)
- Drive 390-0110 was added to Assembly 540-4520 in March 2003.
(WO_26134)
- Drive 390-0110 was not tested in the Netra ct 400/800.
Netra st A1000/D1000 Notes
- The Netra st shipped with 540-4520, 540-4689, 540-5160, and 540-5451.
- 540-4520 replaced 540-4689 in the Netra st A1000/D1000 in September 2001.
(WO_21630)
- 540-5451 replaced 540-4520 in the Netra st A1000/D1000 in June 2002.
(WO_24255)
- Drive 390-0110 was added to Assembly 540-4520 in March 2003.
(WO_26134)
- Drive 390-0110 was not tested in the Netra st A1000/D1000.
Sun Fire V440 Notes
- 46-Byte Drive 390-0110 was removed from Assembly 540-5462 in May 2003.
(WO_26685)
390-0110 is not supported on the V440.
- 96-Byte Drive 390-0156 was added to Assembly 540-5462 (Rev 54) in May 2003.
(WO_26685)
- Assembly 540-5462 with the 96-Byte disk 390-0156 was qualified
on the V440 in January 2004.
See CIR511.
Fujitsu MAP3367NC (36.4GB)
3 1/2" 10000 RPM Low Voltage Differential Ultra-320 SCSI
96 Byte Inquiry (TEC485-2405361)
Go to 46 Byte Inquiry (TEC485-2405331)
Workstations: |
Sun Blade 2500 |
Servers: |
Sun Fire V210, V240, V250, V440, V1280 |
Telco: |
Netra t1400/1405, 1280
Netra ct 400/800, CT 410/810 |
Disk Arrays: |
StorEdge A1000, D1000
StorEdge MultiPack
StorEdge 3310, S1, D2, D240 |
Options 5242 / 5243 / 5244 / 5250 / 5257 / 5261 / 5267 / 5884
Option XTA-3310-36GB-10K
Option XRA-SC1CA-36G10K
390-0156 |
1" Height Allegro 8LE CA06200-B1xx
96 Byte Inquiry TEC485-2405361 |
370-6655 |
540-4520 |
540-4521 |
V20z/V40z FRU 1" Bracket |
12-Slot A1000/D1000 FRU
w 1" Bracket 540-3024
w Plate 340-4288 or 340-5928
or 340-6640 or 340-7269 |
Spud Bracket FRU w 1" Bracket 540-3024 |
540-4689 |
540-4904 |
540-5462 |
ct/CT FRU NEBS Level 3
w 1" Bracket 540-3024
w Plate 340-4288 or 340-5928
or 340-6640 or 340-7269 |
Spud Bracket FRU
w 1" Bracket 540-3024
w Plate 340-5928
or Plate 340-7269 |
Spud Bracket FRU
w 1" Bracket 540-3024
>= Rev 54
See V440 Notes below
|
540-5522 |
540-5693 |
540-5996 |
3300 Series FRU |
Netra t1400/1405 FRU NEBS Level 3
w 1" Bracket 540-3024 |
Spud Bracket FRU
w 1" Bracket 540-3024 |
595-6394 |
StorEdge D240
Left/Right FRU Assembly 599-2593 or Assembly 540-5702
Drive 540-4521 w Bracket 340-6476 |
Notes
- Drive 390-0156 was released in March 2003.
(WO_26685)
- Drive 390-0156 was not tested in Ultra 60/80 or E250/450/220R/420R.
Netra t 1120/1125 Notes
- The Netra t 1120/1125 shipped with 540-4521 and 540-4919.
- 540-4919 replaced 540-4521 in the Netra t 1120/1125 in May 2001.
(WO_20687)
- Drive 390-0156 was added to Assembly 540-4521 in May 2003.
(WO_26685)
- Drive 390-0156 was not tested in the Netra t 1120/1125.
Netra ct 400/800 Notes
- The Netra ct 400/800 shipped with 540-4520 and 540-4689.
- 540-4689 replaced 540-4520 in the Netra ct 400/800 in April 2001.
(WO_20531)
- Drive 390-0156 was added to Assembly 540-4520 in May 2003.
(WO_26685)
- Drive 390-0156 was added to Assembly 540-4689 in July 2003.
(WO_27126)
- Drive 390-0156 was not tested in the Netra ct 400/800 until July 2003.
Netra st A1000/D1000 Notes
- The Netra st shipped with 540-4520, 540-4689, 540-5160, and 540-5451.
- 540-4520 replaced 540-4689 in the Netra st A1000/D1000 in September 2001.
(WO_21630)
- 540-5451 replaced 540-4520 in the Netra st A1000/D1000 in June 2002.
(WO_24255)
- Drive 390-0156 was not tested in the Netra st A1000/D1000.
Sun Fire V440 Notes
- 46-Byte Drive 390-0110 was removed from Assembly 540-5462 in May 2003.
(WO_26685)
390-0110 is not supported on the V440.
- 96-Byte Drive 390-0156 was added to Assembly 540-5462 (Rev 54) in May 2003.
(WO_26685)
- Assembly 540-5462 with the 96-Byte disk 390-0156 was qualified
on the V440 in January 2004.
See CIR511.
|