DC Power Distribution Board
Servers: |
Sun Fire X4100, X4200
Sun Fire X4100 M2, X4200 M2 |
Disk Arrays: |
StorageTek 5220 NAS, 5320 NAS |
|
|
Bus Bar Installation in Pre-Production Systems |
|
|
Bus Bar Installation in Production Systems |
|
Sun Fire X4100 Codename: Galaxy 1U
Sun Fire X4200 Codename: Galaxy 2U
StorageTek 5220 NAS Codename: Thunderbird
StorageTek 5320 NAS Codename: Falcon |
Notes
- Use an 8mm nutdriver (or 5/16") to remove the Bus bar retaining nuts.
- Pre-production systems use four M5 Nuts instead of two Screws and two Nuts.
- Each pre-production Bus Bar has two M5 studs.
- Each production Bus Bar has one M5 stud and one M4 PEM nut.
- Flange Nut 240-5984 replaced Cap Nut 240-4799 in October 2006.
(WO_34488)
- Flange Nut 240-5984 includes a Polyamid insert.
Tighten to 18 in/lb or 2.0 Nm.
- Nut 240-5984 was added to PDB and System Board FRUs in December 2006.
- Manual 819-5035
was added to PDB and System Board FRUs in December 2006.
References
-
Replacement Bus-Bar Nuts Alert, 819-5035.
|