Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Type A208
450 Watt Power Supply

Servers: Sun Fire T2000
SPARC Enterprise T2000

F300-1735

300-1735 300-1817 300-2110
Power One Type A208
AC Input Power Supply
March 2006
L
Tyco Type A208
AC Input Power Supply
March 2006
L
Astec DS450HE
AC Input Power Supply
May 2007
L

AC Input

100-240Vac 50-60Hz 6A RMS Max

DC Output

+12V +3.3Vsb
36.6A 3.1A

Efficiency

220V 100% Load >=88%
220V 75% Load >=88%
220V 50% Load >=84%
220V 30% Load >=84%

Sun Fire T2000 Codename: Ontario
SPARC Enterprise T2000 Codename: Ontario APL

Notes

  1. Power Supply Efficiency affects the current draw in AC Watts from the branch circuit.
    As efficiency increases, the current draw in AC Watts decreases.
  2. To calculate maximum theoretical current draw in AC Watts, multiply the maximum power supply output in DC Watts by the reciprocal of the power supply efficiency.
  3. Theoretical values are typically higher than published values which are based on measured outputs under controlled test conditions.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback