DC Power Distribution Board
341-3166 |
341-3167 |
501-7697 |
501-7951 |
541-2073 |
Blue Gnd Bus Bar
|
Red +12 Bus Bar
|
Horizontal PDB
|
Vertical PDB
|
PDB Assembly/FRU
|
341-3166 |
341-3167 |
511-1603 |
541-4370 |
Blue Gnd Bus Bar
|
Red +12 Bus Bar
|
Horizontal PDB March 2010 |
PDB Assembly March 2010 |
Horizontal PDB 501-7697
|
Vertical PDB 501-7951
|
Sun Fire X4240 Codename: Dorado 2U
Sun Fire X4250 Codename: Doradi 2U
Sun Fire X4270 Codename: Lynx 2U Elwood
Sun Fire X4275 Codename: Lynx 2U Hyde
Sun Fire X4440 Codename: Tucana
Sun Fire X4450 Codename: Tucani
SPARC Enterprise T5220 Codename: Huron 2U
SPARC Enterprise T5240 Codename: Maramba 2U
Storage 7110 Codename: Iwashi
Storage 7410 Codename: Toro
Storage 7410 SAS 2.0 Codename: Amber Road SAS2.0
Oracle Exadata V2 Codename: Quicksilver |
Notes
- PDB <= 501-7697-05 may cause intermittant DVD operation.
- PDB 501-7697-06 changes firmware reset timing for proper DVD operation.
- PDB 501-7697-09 changes firmware to resolve BugID 6806680.
- Access to the Sun Fire X4250 System Board busbar screws is blocked by the
CPU0 Heatsink.
Removal of the CPU0 Heatsink during the PDB replacement procedure is
required.
Clean and re-grease the Heatsink with Thermal Grease Kit F350-1271-01.
The kit includes Cleaning Wipe 250-1802 and ShinEtsu X23-7783D Thermal
Grease syringe 310-0065.
The kit is not included with the PDB.
- PDB 511-1603 only supports a SATA DVD. A PATA DVD is not supported.
- PDB Assembly 541-4370 is not available as a FRU. Use 541-2073.
SPARC Enterprise T5220 and T5240 Notes
- Program the chassis serial number into a replacement PDB
using the setscn command.
Reference the
Service Manual.
See also How To article
1011586.1.
|