FDK PEX821-30
1900 Watt Power Supply

Servers: Sun Fire 6800, E6900

X6800-USIV-KIT / X6800-USIV-KIT-Z

300-1595 300-1930 300-2225
Type A184
AC Input Power Supply
Specification 950-4229
X6800-USIV-KIT
Type A184
AC Input Power Supply
Specification 950-4229
X6800-USIV-KIT-Z
L
Type A184
AC Input Power Supply
Specification 950-4229
X6800-USIV-KIT-Z
L

Front View
      Rear View

AC Input

200/220-240V   12A/10A   47-63Hz

DC Output

1 56.2V 32.5A
2 55.0V 1.45A

Sun Fire 6800 Codename: Serengeti 24
Sun Fire E6900 Codename: Amazon 6

Notes

  1. Sun Fire 6800 shipped with 300-1459.
  2. Sun Fire E6900 ships with 300-1595, 300-1930, 300-1836, or 300-2223.
  3. Sun Fire 6800 requires 300-1595, 300-1930, 300-1836, 300-2223, or 300-2225 with UltraSPARC IV.
    Sun Fire 6800 requires 300-1595, 300-1930, 300-1836, 300-2223, or 300-2225 with 1.8GHz UltraSPARC IV+.
    Sun Fire 6800 and E6900 require 300-1836 or 300-2223 with 1.95GHz UltraSPARC IV+.
  4. Six 300-1595 power supplies are in upgrade kit X6800-USIV-KIT.
    Six 300-2225 power supplies are in upgrade kit X6800-USIV-KIT-Z.
  5. Mixing power supply types is not supported except during an upgrade.
  6. The 300-1930 was replaced by 300-2225 because of DecaBDE in the ejector handle resin.
  7. The European Unions October 12, 2005 exemption 2005/717/EC for use of DecaBDE from Directive 2002/95/EC ended July 1, 2008.
  8. The 300-2225 is not used in new system builds of the E6900 (as of 08/11/08).
  9. The 300-2225 replaced 300-1930 in X6800-USIV-KIT-Z in August 2008. (WO_39675)