Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Delta DPS-1500
1500/1970 Watt Power Supply

Servers: Sun Fire E2900, V1280
Telco: Netra 1290

300-1833
Type A209N
AC Input Power Supply
L

Front View

Rear View

AC Input

Operating 180-264Vrms 47-63Hz 11.6Arms @ 200VAC
Operating 180-264Vrms 47-63Hz 10.0Arms @ 230VAC

DC Output

+48V +12VSB Watts Ambient
40.0A 4.0A 1970W 50C
30.2A 4.0A 1500W 60C

Sun Fire V1280 Codename: Lightweight 8
Sun Fire E2900 Codename: Amazon 2
Netra 1290 Codename: Everglades

Notes

  1. Power Supply slots are labeled PS0, PS1, PS2, and PS3.
  2. At least two dedicated branch circuits should be used.
  3. AC or DC Input Source A provides power to PS0 and PS1.
  4. AC or DC Input Source B provides power to PS2 and PS3.
  5. Mixing the A166 with the A209N is not supported.
  6. The Netra 1290 changed from A166 to A209N in March 2007. (WO_35465)
  7. The A209 is required for 1.8GHz and 1.95GHz configurations.

References

  1. Sun Fire V1280/Netra 1280 Service Manual, 817-0510.
  2. Sun Fire V1280/Netra 1280 System Administration Guide, 817-0509.
  3. Sun Fire V1280/Netra 1280 Systems Site Planning Guide, 817-3333.
  4. Sun Fire V1280/Netra 1280 Systems Installation Guide, 817-3334.
  5. Sun Fire E2900 Site Planning Guide, 817-4052.
  6. Sun Fire E2900 Installation Guide, 817-4053.
  7. Sun Fire E2900 Service Manual, 817-4054.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.