Delta DPS-1500 1500/1970 Watt Power Supply
Servers: |
Sun Fire E2900, V1280 |
Telco: |
Netra 1290 |
300-1833 |
Type A209N AC Input Power Supply L |
Front View
|
Rear View
|
AC Input
Operating 180-264Vrms |
47-63Hz |
11.6Arms @ 200VAC |
Operating 180-264Vrms |
47-63Hz |
10.0Arms @ 230VAC |
DC Output
+48V |
+12VSB |
Watts |
Ambient |
40.0A |
4.0A |
1970W |
50C |
30.2A |
4.0A |
1500W |
60C |
Sun Fire V1280 Codename: Lightweight 8
Sun Fire E2900 Codename: Amazon 2
Netra 1290 Codename: Everglades |
Notes
- Power Supply slots are labeled PS0, PS1, PS2, and PS3.
- At least two dedicated branch circuits should be used.
- AC or DC Input Source A provides power to PS0 and PS1.
- AC or DC Input Source B provides power to PS2 and PS3.
- Mixing the A166 with the A209N is not supported.
- The Netra 1290 changed from A166 to A209N in March 2007.
(WO_35465)
- The A209 is required for 1.8GHz and 1.95GHz configurations.
References
-
Sun Fire V1280/Netra 1280 Service Manual, 817-0510.
-
Sun Fire V1280/Netra 1280 System Administration Guide, 817-0509.
-
Sun Fire V1280/Netra 1280 Systems Site Planning Guide, 817-3333.
-
Sun Fire V1280/Netra 1280 Systems Installation Guide, 817-3334.
-
Sun Fire E2900 Site Planning Guide, 817-4052.
-
Sun Fire E2900 Installation Guide, 817-4053.
-
Sun Fire E2900 Service Manual, 817-4054.
|