Remote System Control (RSC)
Notes
- The minimum operating system is Solaris 2.6 Hardware: 5/98.
- The RSC Flash Prom is on the E250 System Board at U4401.
- Cable 530-2526 is included with 501-4818 and F501-4818.
Power Distribution Board Notes
- If the RSC issues a power-off when the system is Off, the system will be
latched Off. This is fixed on PDB 501-4683-05 Rev 51.
- The RSC may not be able to read the keyswitch position when DC power
is Off. This is fixed on PDB 501-4683-05 Rev 53.
References
-
Enterprise 250 Owners Guide, 805-5160.
-
Remote System Control User's Guide, 805-3722. (11/98)
-
Remote System Control User's Guide, 806-3986. (02/00)
-
Remote System Control 2.0 User's Guide, 806-0426. (01/01)
-
Remote System Control 2.2.2 User's Guide, 816-3314. (08/04)
-
Remote System Control 2.1 Release Notes, 816-0562. (04/01)
-
Remote System Control 2.2 Release Notes, 816-3315. (02/02)
-
Remote System Control 2.2.2 Release Notes, 816-3995. (08/04)
-
Remote System Control Installation Guide, 805-5680. (11/98)
-
Remote System Control Installation Guide, 806-3987. (02/00)
|