400MHz UltraSPARC II Module
Option 1194
501-5237 |
2MB Cache Sapphire-Black |
Notes
- The minimum operating system is Solaris 2.5.1.
- Mixing module cache sizes or speeds is not supported.
- This module is not qualified for use in the Ultra 2.
- The Enterprise 250 requires OBP >=3.12 Version 10.
Enterprise 250 Chassis Notes
- Rear Cardguides installed prior to approx. 2/99 may require replacement to
prevent damage to components on the 400MHz Module. Two guides,
part number 250-1390-01 or 250-1484-01, are included with the module option.
- Chassis <=540-3272-02 is FCC Class B EMI compliant when
250MHz and 300MHz modules are installed.
- Chassis <=540-3272-02 is FCC Class A EMI compliant when
400MHz modules are installed.
- Chassis >=540-3272-03 is FCC Class B EMI compliant when
250MHz, 300MHz, and 400MHz modules are installed.
- Front Bottom Disk Door 540-3352-03 is required for FCC Class B.
- Removable Media Tray 540-3351-02 is required for FCC Class B.
- Chassis 540-3273-03 includes 540-3351-02 and 540-3352-03.
400MHz UltraSPARC II Module
Option 1193
501-5541 |
2MB Cache Sapphire-Black |
Notes
- The minimum operating system is Solaris 2.5.1.
- Mixing module cache sizes or speeds is not supported.
- The Ultra 2 requires System Board >=501-3132-13.
- The Ultra 2 requires OBP >=3.11 Version 2 POST >=3.3.8.
400MHz UltraSPARC II Module
Workstations: |
Ultra 2 |
Servers: |
Enterprise 250 |
Options 1193 / 1194
501-5445 |
2MB Cache Sapphire-Black |
Notes
- The minimum operating system is Solaris 2.5.1.
- Mixing module cache sizes or speeds is not supported.
- The Ultra 2 requires System Board >=501-3132-13.
- The Ultra 2 requires OBP >=3.11 Version 2 POST >=3.3.8.
- The Enterprise 250 requires OBP >=3.12 Version 10.
Enterprise 250 Chassis Notes
- Chassis <=540-3272-02 is FCC Class B EMI compliant when
250MHz and 300MHz modules are installed.
- Chassis <=540-3272-02 is FCC Class A EMI compliant when
400MHz modules are installed.
- Chassis >=540-3272-03 is FCC Class B EMI compliant when
250MHz, 300MHz, and 400MHz modules are installed.
- Front Bottom Disk Door 540-3352-03 is required for FCC Class B.
- Removable Media Tray 540-3351-02 is required for FCC Class B.
- Chassis 540-3273-03 includes 540-3351-02 and 540-3352-03.
400MHz UltraSPARC II Module
Servers: |
Enterprise 450 |
Telco: |
Ultra AXmp |
Options 2244 / 5224
Enterprise 450
501-5239 |
4MB Cache Sapphire-Black X2244A w/o Cover for E450 |
|
Ultra AXmp
501-5420 |
4MB Cache Sapphire-Black SME5224UPA-400
w Cover for Ultra AXmp |
|
Notes
- The minimum operating system is Solaris 2.5.1.
- Mixing module cache sizes or speeds is not supported.
- E450 System Board 501-5270, 501-5672, or 501-5673 is required.
- One E450 DC-DC Converter 300-1322 is required for each module.
- Option 2244 includes 501-5239 and DC-DC Converter 300-1322.
- Empty E450 slot CPU-A1 requires Air Baffle 330-2781 or 330-2805.
- Do NOT install a cover on the 400MHz Module for the E450.
- The 400MHz module is not qualified for the Ultra 450 Workstation.
- The 400MHz module is not compatible with System Board 501-2996.
- 501-5420 is not supported in the Enterprise 450.
See BugID 4357793.
Enterprise 450 Chassis Notes
- Chassis <=540-2833-04 is FCC Class B EMI compliant when
250MHz and 300MHz modules are installed.
- Chassis <=540-2833-04 is FCC Class A EMI compliant when
400MHz modules are installed.
- Chassis >=540-2833-05 is FCC Class B EMI compliant when
250MHz, 300MHz, and 400MHz modules are installed.
- Front Disk Door 540-2832-03 is required for FCC Class B.
- Removable Media Tray 540-2903-03 is required for FCC Class B.
- Chassis 540-2833-05 includes 540-2832-03 and 540-2903-03.
400MHz UltraSPARC II Module
Servers: |
Enterprise 450 |
Telco: |
Ultra AXmp |
Options 2244 / 5224
Enterprise 450
501-5446 |
4MB Cache Sapphire-Black X2244A w/o Cover for A25 |
|
Ultra AXmp
501-5500 |
4MB Cache Sapphire-Black SME5224UPA-400
w Cover for Ultra AXmp |
|
Notes
- The minimum operating system is Solaris 2.5.1.
- Mixing module cache sizes or speeds is not supported.
- E450 System Board 501-5270, 501-5672, or 501-5673 is required.
- One E450 DC-DC Converter 300-1322 is required for each module.
- Option 2244 includes 501-5239 and DC-DC Converter 300-1322.
- Empty E450 slot CPU-A1 requires Air Baffle 330-2781 or 330-2805.
- Do NOT install a cover on the 400MHz Module for the E450.
- The 400MHz module is not qualified for the Ultra 450 Workstation.
- The 400MHz module is not compatible with System Board 501-2996.
- 501-5500 is not supported in the Enterprise 450.
See BugID 4357793.
Ultra Enterprise 450 Chassis Notes
- Chassis <=540-2833-04 is FCC Class B EMI compliant when
250MHz and 300MHz modules are installed.
- Chassis <=540-2833-04 is FCC Class A EMI compliant when
400MHz modules are installed.
- Chassis >=540-2833-05 is FCC Class B EMI compliant when
250MHz, 300MHz, and 400MHz modules are installed.
- Front Disk Door 540-2832-03 is required for FCC Class B.
- Removable Media Tray 540-2903-03 is required for FCC Class B.
- Chassis 540-2833-05 includes 540-2832-03 and 540-2903-03.
400MHz UltraSPARC II Module
501-6070 |
4MB Cache Sapphire-Black w/o Cover |
Notes
- The minimum operating system is Solaris 2.5.1.
- Mixing module cache sizes or speeds is not supported.
- E450 System Board 501-5270, 501-5672, or 501-5673 is required.
- One E450 DC-DC Converter 300-1322 is required for each module.
- Option 2244 includes 501-5446 and DC-DC Converter 300-1322.
- Empty E450 slot CPU-A1 requires Air Baffle 330-2781 or 330-2805.
- The 400MHz module is not qualified for the Ultra 450 Workstation.
- The 400MHz module is not compatible with System Board 501-2996.
Enterprise 450 Chassis Notes
- Chassis <=540-2833-04 is FCC Class B EMI compliant when
250MHz and 300MHz modules are installed.
- Chassis <=540-2833-04 is FCC Class A EMI compliant when
400MHz modules are installed.
- Chassis >=540-2833-05 is FCC Class B EMI compliant when
250MHz, 300MHz, and 400MHz modules are installed.
- Front Disk Door 540-2832-03 is required for FCC Class B.
- Removable Media Tray 540-2903-03 is required for FCC Class B.
- Chassis 540-2833-05 includes 540-2832-03 and 540-2903-03.
|