InfoDoc ID   Synopsis   Date
49700   Repacing disk in A5X00 that is shared by nodes using Sun[TM] Cluster   24 Dec 2002

Status Issued

Description

The best way to obtain informaton on replacing a disk in an A5X00 that is shared by nodes using Sun Cluster is to access documents via http://docs.sun.com site if you do not have hard copy documents.

For Sun[TM] Cluster 3.X see Chapter 16:Sun Cluster 3.0 Hardware Guide

For Sun[TM] Cluster 2.X see Chapter 14:Sun Cluster 2.2 System Administration Guide

For Sun[TM] Cluster 2.X

NOTE: If customer has OPS (Oracle Parallel Server) as opposed to HAOracle(High Availability Oracle) both SSVM/CVM and luxadm commands get run on both nodes, otherwise only luxadm commands are run on both nodes.

NOTE: When running commands that are run on both nodes each command should be run (and allowed to finish) on master/active node first node then the secondary/passive node.

INTERNAL SUMMARY:

Internal Summary

SUBMITTER: Felix Garcia APPLIES TO: ATTACHMENTS: