InfoDoc ID |
|
Synopsis |
|
Date |
20778 |
|
What is the Minimum disk drive configuration for the A5X00? |
|
20 Oct 1999 |
Below is the minimum disk configuration supported on the A5X00 disk
arrays.
14-slot array
-------------
In the minimum disk drive configuration for the 14-slot disk array,
disk drives are shipped in rear backplane slots 0, 3, and 6 as well
as front backplane slots 3 and 6.
22-slot array
-------------
In the minimum disk drive configuration for the 22-slot disk array,
disk drives are shipped in rear backplane slots 0, 3, 6, and 10 as well
as front backplane slot 0, 5, and 10.
======================================================
DO NOT MOVE DISK DRIVES FROM THE MINIMUM CONFIGURATION
======================================================
For additional information, please see the Sun StorEdge A5000 Installation
and Service Manual, P/N 802-7573 Chapter 1.
SUBMITTER: Dan Auga
APPLIES TO: Hardware, AFO Vertical Team Docs, AFO Vertical Team Docs/Hardware
ATTACHMENTS: