This section provides the most common repair procedures for the 
  Ultra 10 workstation. The written procedures below are links to the 
Sun 
  Ultra 10 Service Manual (805-7764).
   
    | Component | 
     
       Remove 
     | 
     
       Install 
     | 
    Tips | 
  
   
    | CD-ROM Drive | 
     
      
     | 
     
      
     | 
     
      
        - Booting from CD-ROM on Ultra 5/10 systems might not succeed unless 
          the system OBP is updated (FIN I0770-1).
 
       
     | 
  
   
    | CPU Fan Assembly | 
     
      
     | 
     
      
     | 
      | 
  
   
    | CPU Module | 
     
      
     | 
     
      
     | 
     
      
        - The system board must have the minimum OBP version (3.19v4) installed 
          for the Ultra 5/10 333MHZ Sapphire Red CPU module; otherwise, the system 
          will be non-operational (FIN I0528-1).
 
        - Unable to boot after replacing CPU in Ultra 5/10 (SRDB 21117).
 
       
     | 
  
   
    | Disk Drive | 
     
      
     | 
     
      
     | 
     
      
        - When installing dual hard drives, the IDE cabling instructions in 
          some Ultra 10 manuals are incorrect. See the Sun Ultra 10 Product Note 
          (
 806-4928) for the correct instructions. 
        -  The 
 Hard 
          Drive Mirroring section describes the requirements and constraints 
          of a hard drive mirroring solution that utilizes Solstice DiskSuite 
          software.  
        - Ultra 5/10 workstations may encounter uncorrectable data errors on 
          IDE disks during boot after using shutdown -y -i5 -g0 command (FIN I0779-1).
 
        - Secondary disk drives won't be recognized with IBM 9 GB disk drive 
          as a primary and both configured with "master" (FIN I0568-1).
 
        - After adding or replacing a disk drive, the following error occurs 
          when attempting to use the format utility: "corrupt label - wrong magic 
          number" (FIN I0385-1).
 
        - Mirrored 20GB disk drives on Ultra 10 and Sun Blade 100 systems may 
          be exposed to a drive compatibility issue when replacing a failed drive 
          ( FCO A0202-1).
 
        - 18GB and 36GB IBM disk drives experiencing high failure rate in high 
          humidity and high temperature environments (FCO A0182-1).
 
       
     | 
  
   
    | Floppy Drive | 
     
      
     | 
     
      
     | 
      | 
  
   
    | Front Bezel | 
     
      
     | 
     
      
     | 
      | 
  
   
    | Graphics Card | 
     
      
     | 
     
      
     | 
      | 
  
   
    | Power Supply | 
     
      
     | 
     
      
     | 
      | 
  
   
    | Speaker Assembly | 
     
      
     | 
     
      
     | 
      | 
  
   
    | Memory (DIMM) | 
     
      
     | 
     
      
     | 
     
      
        - Ultra 5 and Ultra 10 systems might not boot if Micron memory and OBP 
          3.25.2 (or earlier) are installed (FIN I0598-1).
 
       
     | 
  
   
    | NVRAM/TOD | 
     
      
     | 
     
      
     | 
     
      
        - New NVRAM (525-1817) is incompatible with the Ultra 5/10 system board 
          (375-0079), so a new system board (375-0115) was created for the new 
          NVRAM (I0596-1). 
        
 
       
     | 
  
   
    | PCI Card | 
     
      
     | 
     
      
     | 
     
      
        - 
          
 
            SunPCi II and SunPCi IIpro cards may not respond 
              after rapid/successive power cycling (FCO  A0186-1).  
           
         
        - PCI cards in Ultra 10 not accessible due to mechanical alignment and 
          seating problems with the PCI Riser card (FCO A0152-1).
 
        - Ultra 5/10 systems may encounter errors when booting from SCSI devices 
          attached to Dual Ultra SCSI PCI cards (FIN I0386-1).
 
       
     | 
  
   
    | PCI Riser Board | 
     
      
     | 
     
      
     | 
      | 
  
   
    | System Board | 
     
      
     | 
     
      
     | 
      |