Sun Fire[tm] V480: Configuration Information
 
  Disk Backplane Cabling Notes: 
  - When Loop B is configured, the external Port 1 of X6727A (375-3030) card
      cannot be used for additional external storage. This would extend the
      internal loop B outside of the box, which is not supported. Making use
      of the second external port off X6727A is supported.
 
 
Multi-Pathing Notes:
  
  - Multi-pathing configurations on the V480's internal subsystem MUST be
      managed by Veritas VxDMP.
 
  - MPxIO is not a viable solution at this time, due to the restriction
      that prevents it from supporting a boot disk.
 
  - Any V480 that requires multi-pathing to the internal storage array may
      be quoted at a workgroup license fee rather than the departmental
      license fee.
 
 
 |