| Processor | 
  
   
    | Number | 
    Up to eight | 
  
   
    | Architecture | 
     
       750 MHz UltraSPARC[tm] III (64-bit) 
        900 MHz UltraSPARC III (64 bit) 
     | 
  
   
    | Memory Management | 
    MMU with 64 I-TLB entries and 64 D-TLB entries, 8192 hardware-supported 
      contexts | 
  
   
    | Cache memory | 
     
       64-KB data and 32-KB instruction on chip per processor  
      Secondary: 8-MB external per processor 
     | 
  
   
    | Main 
      Memory  | 
  
   
    | Capacities | 
     
       Total of 16 DIMM memory slots available per CPU/Memory board 
      128, 256, 512 MB, or 1GB* (16GB maximum per CPU/Memory board, 64GB maximum 
        when configured with 8 processors) 
      * - 1GB DIMMs only supported on 900MHz CPU/Memory boards. 
        Note: Install DIMMs in groups of four 
     | 
  
   
    | Memory type | 
    232-Pin 7-nS memory modules | 
  
   
    | Standard 
      Interfaces  | 
  
   
    | Ethernet | 
     
      
        - One Gigabit ethernet (1000BASE-T) dual SC fiber optic port
 
        -  One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair standard 
          connector (RJ-45)
 
       
     | 
  
   
    | Keyboard and mouse | 
    USB (uses one of the two standard USB 
      (Type A) port) | 
  
   
    | PCI | 
     
       Nine full sized, hot-swap, PCI slots compliant with PCI specification 
        Revision 2.1:  
      
        - Two slots operating at 66-MHz, 64 or 32 bits wide, 3.3 volts
 
        - Seven slot operating at 33-MHz, 64 or 32 bits wide, 5 volts
 
       
     | 
  
   
    | Remote System Controller | 
    One RSC card plugs into a dedicated slot on the system I/O board which 
      includes integrated modem, serial and Ethernet interfaces. 
      
        - One 56 Kbps modem port (RJ-11)
 
        - One EIA-232D serial port (RJ-45)
 
        - One 10 Mbps Ethernet port (RJ-45)
 
       
     | 
  
   
    | Serial | 
    Two RS-232D/RS-423 serial ports (DB25) 
      via splitter cable (X985A) | 
  
   
    | USB | 
    Two standard Universal Serial Bus (USB) 
      Type A connectors | 
  
   
    | Internal 
      Mass Storage | 
  
   
    | Host Adapters | 
     
       Internal SCSI to support the internal DVD and optional removable media 
        devices 
      Up to nine PCI-to-dual FC-AL adapters or PCI-to-UltraSCSI adapters 
     | 
  
   
    | Disks | 
    Up to 12 3.5" x 1" 10000 RPM FC-AL disks, 36.4GB, 
      or 73.4GB capacity. Maximum total capacity of 876GB. | 
  
   
    | DVD-ROM | 
    10X DVD-ROM (standard) | 
  
   
    | Tape | 
    Optional 12GB DDS3 4mm or 20GB DDS4 4mm single drive | 
  
   
    | Power 
      Supplies  | 
  
   
    | Type | 
    2 minimum, 3 for N+1 redundancy, individual power cords | 
  
   
    | Output | 
    1100W maximum per power supply | 
  
   
    | Environment | 
  
   
    | AC input | 
    100 - 240 VAC, 47 - 63 Hz, 15 A (max) per power cord, 1.48 KVA per power 
      supply (3.5 KVA) | 
  
   
    | Input power | 
    3000 W | 
  
   
    | Heat output | 
     Base Configuration: 2,867 BTU/hr 
      Maximum Configuration: 6,563 BTU/hr 
      See Infodoc 48584 
      for more specific details. | 
  
   
    | Temperature | 
     Operating: 5° C to 35° C (41° F to 95° F) 
      Nonoperating: -20° C to 60° C (-4° F to 140° F)  | 
  
   
    | Humidity | 
     Operating: 20% to 80% relative humidity, noncondensing 
      Nonoperating: 5% to 93% relative humidity, noncondensing | 
  
   
    | Altitude | 
     Operating: 3000 m (10,000 ft.) 
      Nonoperating: 12,000 m (40,000 ft.)  | 
  
   
    | Acoustic noise | 
     Operating: 6.7 bels 
      Idling: 7.6 bels | 
  
   
    | Vibration | 
     Operating: 0.0002 G2/Hz, 5 - 500 Hz 
      (random) (deskside) 
      0.00015 G2/Hz, 5 - 500 Hz (random) (rackmounted) 
       
      Nonoperating: 0.002 G2/Hz, 5 - 500 Hz (random) 
      (deskside) 
      0.0015 G2/Hz, 5 - 500 Hz (random) (rackmounted) 
     | 
  
   
    | Shock | 
     Operating: 4 G peak, 11 milliseconds half-sine pulse (deskside) 
      3 G peak, 11 milliseconds half-sine pulse (rackmounted)  
      Nonoperating: 15 G peak, 11 milliseconds half-sine pulse (deskside) 
      10 G peak, 11 milliseconds half-sine pulse (rackmounted)  | 
  
   
    | Number of cords | 
    3 | 
  
   
    | Plug type - U.S. | 
    NEMA 5-15P | 
  
   
    | Plug type - International | 
    IEC 320, 10 A | 
  
   
     Regulations 
      Meets or exceeds the following requirements: | 
  
   
    | Safety | 
    UL 60950, CSA C22.2, EN 60950 (from UL), TUV 60950, UL CB 
      Scheme IEC 950 (CE Mark), GOST | 
  
   
    | RFI/EMI | 
    Class A:Australia/New Zealand AS/NZ 3548, Industry Canada 
      ICES-003,European Community EN55022/CISPR22,Japan VCCI,Taiwan CNS 13438,and 
      US FCC 47CFR15.B | 
  
   
    | Immunity | 
    EN55024,i.e.EN61000-4-2,EN61000-4-3, EN61000-4-4,EN61000-4-5,EN61000-4-6, 
      EN61000-4-8,and EN61000-4-11 | 
  
   
    | X-ray | 
    US DHHS 21 CFR Subchapter J, PTB German X-ray Decree | 
  
   
    | Dimensions 
      and Weights | 
  
   
    | Height1 | 
    71.4 cm (28.1 in.) with castors | 
  
   
    | Width | 
    48.0 cm (18.9 in.) | 
  
   
    | Depth | 
    83.6 cm (32.9 in.) | 
  
   
    | Weight | 
    88.1 kg (194.0 lb.)(minimum, approximate) 
      130.9 kg (288.0 lb.)(maximum, approximate) | 
  
   
    | Power Cord | 
     2.5 m (8.2 ft.) | 
  
   
    |  1 Rackmounting does 
      not require the removal of castors. | 
  
   
    | Clearance 
      and Service Access | 
  
   
    | Front | 
     Deskside - 91 cm (36 in.) 
      Rackmount - 122 cm (48 in.)  | 
  
   
    | Rear | 
    91 cm (36 in.) | 
  
   
    | Right | 
    91 cm (36 in.) | 
  
   
    | Left | 
    91 cm (36 in.) | 
  
   
    | Rack 
      Mounting  | 
  
   
    | Fits into a standard commercial 19-inch wide, 36-inch deep 
      rack, but in third party racks, the front and rear doors must be at least 
      63% open area for the Sun Fire V880 to cool properly. To facilitate rack 
      mounting, heavier components such as power supplies may be removed. |