| Processor | 
  
   
    | Number | 
    Two to 24 | 
  
   
    | Architecture | 
    750 MHz, 900 MHz, or 1050MHz UltraSPARC[tm] Cu (copper based) III | 
  
   
    | Cache per processor | 
    Primary (L1): 32 KB instruction, and 64 KB data cache  
      Secondary (L2): 8 MB, ECC protected | 
  
   
    | CPU interface | 
    Packet-switch crossbar connecting up to 6 CPU/Memory boards, and up to 
      4 I/O assemblies | 
  
   
    | System Interconnect | 
    Fireplane, 9.6 GB/sec (at 150 MHz) | 
  
   
    | System 
      Boards | 
  
   
    | Number of boards | 
    Maximum of 6 CPU/Memory boards and 4 I/O assemblies | 
  
   
    | CPU/Memory board | 
    Two CPU's with 16 GB (max) Memory or four CPU's with 32 GB (max) memory  | 
  
   
    | PCI I/O Assembly | 
    Eight PCI slots supporting 6 full or short cards (4 at 33 MHz, 5V and 
      2 at 66/33 MHz, 3.3V) and 2 short boards (at 33 MHz, 5V) | 
  
   
    | CompactPCI I/O Assembly | 
    Four CompactPCI slots supporting 4-3U cPCI cards (2 at 33 MHz, 5V and 
      2 at 66/33 MHz, 3.3V) | 
  
   
    | Main 
      Memory | 
  
   
    | 32 GB memory (max) per 4 CPU's or 16 GB memory (max) per 2 
      CPU's on a CPU/Memory board 
       Maximum system memory capacity of 192 GB (6 x 32 GB) 
       Note: The UltraSPARC III processor contains an integrated memory controller 
        which is responsible for memory management of local memory and for running 
        diagnostics on the CPU/Memory board. Therefore, memory capacity is directly 
        related to the number of CPU's. 
      | 
  
   
    | Standard 
      Interfaces | 
  
   
    | System Controller | 
    Responsible for the overall control of the system. Each System Controller 
      includes one RS-232/423 (DB25) 
      serial interface and one 10/100BASE-T ethernet/fast ethernet (RJ45) 
      interface. Dual system controllers are standard on the Sun Fire 6800. | 
  
   
    | Internal 
      Mass Storage | 
  
   
    | Sun StorEdge[tm] D240 Media Tray | 
    A 2U-high, rack-mounted unit into which two UltraWide SCSI3 disk drive, 
      and one DVD drive and one DDS4 tape drive can be fitted. The DVD and DDS4 
      devices can be replaced by extra disk drives if required. Up to 3 - D240 
      trays can be installed into the Sun Fire 6800 cabinet. | 
  
   
    | Power 
      Supplies | 
  
   
    | The Sun Fire 3800-6800 server family can be configured with 
      N"4" redundant DC bulk power supplies, which are hot swappable. The DC bulk 
      power supplies provide power for all of the Sun Fire 3800-6800 systems' 
      internal requirements, on a load-shared 48VDC power bus. The base package 
      comes with 6 power supplies. | 
  
   
    | Environment | 
  
   
    | AC power | 
    200 - 240 VAC, 47 - 63 Hz, 34 A with 2 RTS | 
  
   
    | Input power | 
    6,460 W | 
  
   
    | Heat output | 
    22,030 BTU/hr | 
  
   
    | Temperature | 
    Optimal: 21° C to 23° C (70° F to 73.5° F) 
      Operating: 5° C to 35° C (41° F to 95° F) - derate 
      2° C for every 1 km up to 3 km 
       Nonoperating: -20° C to 60° C (-4° F to 140° F) | 
  
   
    | Humidity | 
    Optimal: 45% to 50% relative humidity 
      Operating: 20% to 80% relative humidity, noncondensing 
      Nonoperating: 5% to 93% relative humidity, noncondensing | 
  
   
    | Acoustic noise | 
    69 dB(A) | 
  
   
    | Vibration | 
    Operating: 0.15 G, 5 to 500Hz, swept sine 
      Nonoperating: 0.6 G, 5 to 500Hz, swept sine, vertical 
      0.3 G, 5 to 500Hz, swept sine, horizontal  | 
  
   
    | Shock | 
    Operating: 3 G, 11 ms, half sine | 
  
   
    | Plug type - US | 
    NEMA L6-30P, 200 - 240 VAC | 
  
   
    | Plug type - International | 
    32 A, IEC309, 200 - 240 VAC | 
  
   
    | Number of cords1 | 
    2 or 4 (dual power grid feature) | 
  
   
    | 1 One power cord 
      for each RTS installed. Minimum required is two and maximum is four. | 
  
   
    Regulations 
       
      Meets or exceeds the following requirements: | 
  
   
    | Safety | 
    UL 1950, CSA C22.2 950, TUB EN60950, CB Scheme (Worldwide Deviation) | 
  
   
    | RFI/EMI | 
    FCC Class A, ICES 003 Class A, DOC Class A, EN55022 Class A, VCCI Class 
      A, BSMI Class A, EN61000-3-2 & EN61000-3-3 | 
  
   
    | Immunity | 
    EN55024, EN50082-1 | 
  
   
    | Dimensions 
      and Weights | 
  
   
    | Height | 
     75.00 in, 190.5 cm | 
  
   
    | Width | 
     24.00 in, 61.0 cm | 
  
   
    | Depth | 
     53.00 in, 134.6 cm | 
  
   
    | Weight, main cabinet | 
     1000 lbs, 454 kg | 
  
   
    | Power Cord | 
     180 in (15 ft), 457.2 cm (4.6 m) | 
  
   
    | Clearance 
      and Service Access | 
  
   
    | Front | 
    4 ft (121 cm) | 
  
   
    | Rear | 
    3 ft (91 cm) | 
  
   
    | Right | 
    0 clearance during operation* | 
  
   
    | Left | 
    0 clearance during operation* | 
  
   
    | * To access and remove side panels, allow approximately 2 
      ft (60 cm.) of space on the sides. For any peripheral tray in the processor 
      cabinet OVER 508 mm (20 in) in length, allow additional space for access 
      to the doors on the side where the peripheral will be loaded. |