| Processor | 
  
   
    | Number | 
    Two to 12 | 
  
   
    | Architecture | 
    750 MHz, 900 MHz, or 1050MHz UltraSPARC[tm] 
      Cu (copper based) III  | 
  
   
    | Cache per processor | 
    Primary (L1): 32 KB instruction, and 64 
      KB data cache  
      Secondary (L2): 8 MB, ECC protected | 
  
   
    | CPU interface | 
    Packet-switch crossbar connecting up to 
      3 CPU/Memory boards, and up to 2 I/O assemblies | 
  
   
    | System Interconnect | 
    Fireplane, 9.6 GB/sec (at 150 MHz) | 
  
   
    | System 
      Boards | 
  
   
    | Number of boards | 
    Maximum of 3 CPU/Memory boards and 2 I/O 
      assemblies | 
  
   
    | CPU/Memory board | 
    Two CPU's with 16 GB (max) Memory or four 
      CPU's with 32 GB (max) memory  | 
  
   
    | PCI I/O Assembly | 
    Eight PCI slots supporting 6 full or short 
      cards (4 at 33 MHz, 5V and 2 at 66/33 MHz, 3.3V) and 2 short boards (at 
      33 MHz, 5V) | 
  
   
    | CompactPCI I/O Assembly | 
    Four CompactPCI slots supporting 4-3U cPCI 
      cards (2 at 33 MHz, 5V and 2 at 66/33 MHz, 3.3V) | 
  
   
    | Main Memory | 
  
   
    | 32 GB memory (max) per 4 CPU's or 16 GB memory (max) per 2 
      CPU's on a CPU/Memory board 
       Maximum system memory capacity of 96 GB (3 x 32 GB) 
       Note: The UltraSPARC III processor contains an integrated memory controller 
        which is responsible for memory management of local memory and for running 
        diagnostics on the CPU/Memory board. Therefore, memory capacity is directly 
        related to the number of CPU's. 
      | 
  
   
    | Standard 
      Interfaces | 
  
   
    | System Controller | 
    Responsible for the overall control of the 
      system. Each System Controller includes one RS-232/423 (DB25) 
      serial interface and one 10/100BASE-T ethernet/fast ethernet (RJ45) 
      interface. Dual system controllers are standard on the Sun Fire 6800. | 
  
   
    | Internal 
      Mass Storage | 
  
   
    | Sun StorEdge[tm] D240 Media Tray | 
    A 2U-high, rack-mounted unit into which 
      two UltraWide SCSI3 disk drive, and one DVD drive and one DDS4 tape drive 
      can be fitted. The DVD and DDS4 devices can be replaced by extra disk drives 
      if required. Up to 2 - D240 trays can be installed into the Sun Fire 4800/4810 
      cabinet. | 
  
   
    | Power 
      Supplies | 
  
   
    | The Sun Fire 3800-6800 server family can 
      be configured with N"4" redundant DC bulk power supplies, which are hot 
      swappable. The DC bulk power supplies provide power for all of the Sun Fire 
      3800-6800 systems' internal requirements, on a load-shared 48VDC power bus. 
      The base package comes with 2 power supplies. | 
  
   
    | Environment | 
    4800 | 
    4810 | 
  
   
    | AC input | 
    200-240 VAC, 47-63 Hz, 16 A(per power cord) | 
    200 - 240 VAC, 47 - 63 Hz, 16.4 A(per power 
      cord)  | 
  
   
    | Input power | 
    3,040 W | 
    3,120 W | 
  
   
    | Heat output | 
    10,370 BTU/hr | 
    10,625 BTU/hr | 
  
   
    | Temperature | 
    Optimal: 21° C to 23° C (70° 
      F to 73.5° F) 
      Operating: 5° C to 35° C (41° F to 95° F) - derate 
      2° C for every 1 km up to 3 km 
       Nonoperating: -20° C to 60° C (-4° F to 140° F) 
     | 
    Optimal: 21° C to 23° C (70° 
      F to 73.5° F) 
      Operating: 5° C to 35° C (41° F to 95° F) - derate 
      2° C for every 1 km up to 3 km 
      Nonoperating: -20° C to 60° C (-4° F to 140° F) 
   | 
   
    | Humidity | 
     Optimal: 45% to 50% relative humidity 
      Operating: 20% to 80% relative humidity, noncondensing 
      Nonoperating: 5% to 93% relative humidity, noncondensing | 
    Optimal: 45% to 50% relative humidity 
      Operating: 20% to 80% relative humidity, noncondensing 
      Nonoperating: 5% to 93% relative humidity, noncondensing | 
  
   
    | Altitude | 
    Operating: 3000 m (10,000 ft.) 
      Nonoperating: 12,000 m (40,000 ft.) | 
    Operating: 3000 m (10,000 ft.) 
      Nonoperating: 12,000 m (40,000 ft.) | 
  
   
    | Acoustic noise | 
    69 dB(A) | 
    69 dB(A) | 
  
   
    | Vibration | 
    Operating: 0.15 G, 5 to 500Hz, swept sine 
      Nonoperating: 0.6 G, 5 to 500Hz, swept sine, vertical 
      0.3 G, 5 to 500Hz, swept sine, horizontal  | 
    Operating: 0.15 G, 5 to 500Hz, swept sine 
      Nonoperating: 0.6 G, 5 to 500Hz, swept sine, vertical 
      0.3 G, 5 to 500Hz, swept sine, horizontal  | 
  
   
    | Shock | 
    Operating: 3 G, 11 ms, half sine | 
    Operating: 3 G, 11 ms, half sine | 
  
   
    | Number of cords1 | 
    Deskside: 3 
      Rack Mounted: 2 | 
    Deskside: 3 
      Rack Mounted: 2 | 
  
   
    | Plug type - US | 
    Deskside: NEMA 6-15P 
      Rack Mounted: L6-30P | 
    Deskside: NEMA 6-15P 
      Rack Mounted: L6-30P  | 
  
   
    | Plug type - International | 
    10A, single phase IEC320, 200 - 240 VAC | 
    10A, single phase IEC320, 200 - 240 VAC | 
  
   
    | 1 One power cord 
      for each power supply installed. Minimum required is two and maximum is 
      three. | 
  
   
    Regulations 
       
      Meets or exceeds the following requirements: | 
  
   
    | Safety | 
    UL 1950, CSA C22.2 950, TUB EN60950, CB 
      Scheme (Worldwide Deviation) | 
  
   
    | RFI/EMI | 
    FCC Class A, ICES 003 Class A, DOC Class 
      A, EN55022 Class A, VCCI Class A, BSMI Class A, EN61000-3-2 & EN61000-3-3 | 
  
   
    | Immunity | 
    EN55024, EN50082-1 | 
  
   
    | Dimensions and Weights | 
    4800 | 
    4810 | 
  
   
    | Height | 
    32.40 in, 82.3 cm (deskside)  
      30.00 in, 76.2 cm (rack-mount) | 
    36.75 in, 93.4 cm | 
  
   
    | Width  | 
    18.90 in, 48.1 cm (deskside)  
      17.56 in, 44.6 cm (rack-mount) | 
    17.56 in, 44.6 cm | 
  
   
    | Depth  | 
    34.20 in, 86.9 cm (deskside)  
      28.50 in, 72.4 cm (rack-mount) | 
    23.62 in, 60.0 cm | 
  
   
    | Weight  | 
    290 lbs, 131 kg (deskside)  
      275 lbs, 125 kg (rack-mount) | 
    290 lbs, 132 kg | 
  
   
    | Clearance and Service Access 
      (4800/4810 Rack-mounted)  | 
  
   
    | Front | 
    4 ft (121 cm) | 
  
   
    | Rear | 
    3 ft (91 cm) | 
  
   
    | Right | 
    0 clearance during operation* | 
  
   
    | Left | 
    0 clearance during operation* | 
  
   
    | * To access and remove side panels, allow 
      approximately 2 ft (60 cm.) of space on the sides.  | 
  
   
    | Clearance and Service Access 
      (4800 Deskside) | 
  
   
    | Front | 
    3 ft (91 cm) | 
  
   
    | Rear | 
    3 ft (91 cm) | 
  
   
    | Right | 
    1 in (25 mm) | 
  
   
    | Left | 
    1 in (25 mm) | 
  
   
    | Rack | 
  
   
    4800: Fits into standard 19-inch 
      wide, 36-inch deep commercial racks. 
      4810: Fits into 19 inch wide, 30 inch racks. |