| Processor | 
  
   
    | Number | 
    Two to 8 | 
  
   
    | Architecture | 
    750 MHz, 900MHz, or 1050MHz UltraSPARC[tm] Cu (copper based) III  | 
  
   
    | Cache per processor | 
    Primary (L1): 32 KB instruction, and 64 KB data cache  
      Secondary (L2): 8 MB, ECC protected | 
  
   
    | CPU interface | 
    Packet-switch crossbar connecting up to 6 CPU/Memory boards, and up to 
      4 I/O assemblies | 
  
   
    | System Interconnect | 
    Fireplane, 9.6 GB/sec (at 150 MHz) | 
  
   
    | System 
      Boards | 
  
   
    | Number of boards | 
    Maximum of 2 CPU/Memory boards and 2 I/O assemblies | 
  
   
    | CPU/Memory board | 
    Two CPU's with 16 GB (max) Memory or four CPU's with 32 GB (max) memory  | 
  
   
    | PCI I/O Assembly | 
    n/a | 
  
   
    | CompactPCI I/O Assembly | 
    Six CompactPCI slots supporting 6-3U cPCI cards (4 at 33 MHz, 5V and 2 
      at 66/33 MHz, 3.3V) | 
  
   
    | Main 
      Memory | 
  
   
    | 32 GB memory (max) per 4 CPU's or 16 GB memory (max) per 2 
      CPU's on a CPU/Memory board 
       Maximum system memory capacity of 64 GB (2 x 32 GB) 
       Note: The UltraSPARC III processor contains an integrated memory controller 
        which is responsible for memory management of local memory and for running 
        diagnostics on the CPU/Memory board. Therefore, memory capacity is directly 
        related to the number of CPU's. 
      | 
  
   
    | Standard 
      Interfaces | 
  
   
    | System Controller | 
    Responsible for the overall control of the system. Each System Controller 
      includes one RS-232/423 (DB25) 
      serial interface and one 10/100BASE-T ethernet/fast ethernet (RJ45) 
      interface. Dual system controllers are standard on the Sun Fire 6800. | 
  
   
    | Internal 
      Mass Storage | 
  
   
    | Sun StorEdge[tm] D240 Media Tray | 
    A 2U-high, rack-mounted unit into which two UltraWide SCSI3 disk drive, 
      and one DVD drive and one DDS4 tape drive can be fitted. The DVD and DDS4 
      devices can be replaced by extra disk drives if required. | 
  
   
    | Power 
      Supplies | 
  
   
    | The Sun Fire 3800-6800 server family can be configured with 
      N"4" redundant DC bulk power supplies, which are hot swappable. The DC bulk 
      power supplies provide power for all of the Sun Fire 3800-6800 systems' 
      internal requirements, on a load-shared 48VDC power bus. The base package 
      comes with 2 power supplies. | 
  
   
    | Environment | 
  
   
    | AC input | 
    100 VAC: 47 - 63 Hz, 24 A (max configuration) 
      120 VAC: 47 - 63 Hz, 19.7A (max configuration) 
      200 - 240 VAC: 47 - 63 Hz, 11.4 A (max configuration)  | 
  
   
    | Input power | 
     100 VAC: 2280 W 
      120 VAC: 2240 W 
      200 - 240 VAC: 2170 W | 
  
   
    | Heat output | 
     100 VAC: 7775 BTU/hr 
      120 VAC: 7645 BTU/hr 
      200 - 240 VAC: 7385 BTU/hr | 
  
   
    | Temperature | 
    Optimal: 21° C to 23° C (70° F to 73.5° F) 
      Operating: 5° C to 35° C (41° F to 95° F) - derate 
      2° C for every 1 km up to 3 km 
      Nonoperating: -20° C to 60° C (-4° F to 140° F) | 
  
   
    | Humidity | 
     Optimal: 45% to 50% relative humidity 
      Operating: 20% to 80% relative humidity, noncondensing (27° C 
      max wet bulb) 
      Nonoperating: 5% to 93% relative humidity, noncondensing (38° 
      C max wet bulb) | 
  
   
    | Altitude | 
     Operating: 3000 m (10,000 ft.) 
      Nonoperating: 12,000 m (40,000 ft.)  | 
  
   
    | Acoustic noise | 
     Operating: 6.9 bels | 
  
   
    | Vibration | 
     Operating: 0.15 G, 5 - 500 Hz (swept sine) 
      Nonoperating: 0.6 G, 5 - 500 Hz (swept sine), vertical axis 
      0.3 G, 5 - 500 Hz (swept sine), horizontal axis | 
  
   
    | Shock | 
    Operating: 3 G peak, 11 milliseconds half-sine pulse | 
  
   
    | Number of cords1 | 
    3 | 
  
   
    | Plug type - U.S. | 
    NEMA 5-15P, 100 - 120 VAC 
      NEMA 6-15P, 200 - 240 VAC  | 
  
   
    | Plug type - International | 
    IEC 320, 15 A, 200 - 240 VAC | 
  
   
    | 1 One power cord 
      for each power supply installed. Minimum required is two and maximum is 
      three. | 
  
   
    Regulations 
       
      Meets or exceeds the following requirements: | 
  
   
    | Safety | 
    UL 1950, CSA 950, TUB EN60950, CB Scheme (Worldwide Deviation) | 
  
   
    | RFI/EMI | 
    FCC Class A, ICES 003 Class A, DOC Class A, EN55022 Class A, VCCI Class 
      A, BSMI Class A, EN61000-3-2 & EN61000-3-3 | 
  
   
    | Immunity | 
    EN55024, EN50082-1 | 
  
   
    | Harmonics | 
    EN61000-3-2 | 
  
   
    | Dimensions 
      and Weights | 
  
   
    | Height | 
     38.1 cm (15.0 in.) 
      85.7 cm (33.75 in.) shipping | 
  
   
    | Width | 
     45 cm (17.72 in.) 
      63 cm (24.75 in.) shipping | 
  
   
    | Depth | 
     88.4 cm (34.8 in.) 
      105.5 cm (41.5 in.) shipping | 
  
   
    | Weight | 
     104 kg (230 lb.) approximate 
      117.9 kg (260 lb.) approximate shipping | 
  
   
    | Power Cord | 
     2.5 m (8.2 ft.) | 
  
   
    | Clearance 
      and Service Access | 
  
   
    | Front | 
     121 cm (4 ft.) | 
  
   
    | Rear | 
     91 cm (3 ft.) | 
  
   
    | Right1 | 
    0 clearance during operation | 
  
   
    | Left1 | 
    0 clearance during operation | 
  
   
    |  1 To access and 
      remove side panels, allow approximately 60 cm (2 ft.) of space on the sides. | 
  
   
    | Rack | 
  
   
    | Fits into 19-inch wide, 40-inch deep commercial 
      racks. |