| Processor | 
  
   
    | Number | 
    Sun Fire 12K: 4 to 52 
      Sun Fire 15K: 16 to 106 | 
  
   
    | Architecture | 
    900 MHz or 1050MHz UltraSPARC[tm] III CPU, ECC protected | 
  
   
    Cache per processor 
      Level 1 
      Level 2 | 
     
      ECC protected 32 KB instruction and 64 KB data on chip 
      ECC protected 8 MB external cache  | 
  
   
    | System Interconnect | 
    150 MHz Sun[tm] Fireplane redundant 18X18 data, address, and 
      response crossbar interconnect | 
  
   
    | System 
      Boards  | 
  
   
    | CPU/Memory Boards | 
    Sun Fire 12K: Up to 9 CPU/Memory boards, each holding 
      4 processors and up to 32GB memory (32 DIMMs per board, 8 banks of 4 DIMMS), 
      providing up to 288GB memory per system, and common design across the entire 
      Sun Fire 3800 - 15K server line. 
      Sun Fire 15K: Up to 18 CPU/Memory boards, each holding 4 processors 
      and up to 32GB memory (32 DIMMs per board, 8 banks of 4 DIMMS), providing 
      up to 576GB memory per system, and common design across the entire Sun Fire 
      3800 - 15K server line. | 
  
   
    | I/O | 
    Sun Fire 12K: 9 I/O hubs support up to 36 I/O hot-swappable 
      PCI slots. 18 slots are 66MHz, 18 slots are 33MHz. 
      Sun Fire 15K: 18 I/O hubs support up to 72 I/O hot-swappable PCI 
      slots. 36 slots are 66MHz, 36 slots are 33MHz. | 
  
   
    | System Controller (SC) | 
    2 redundant system controllers. Automatic system failover of 
      system controllers, automatic failover of SC clock and management functions, 
      with no service interruption to users. | 
  
   
    | Main 
      Memory | 
  
   
    Sun Fire 12K: 8GB to 288GB memory capacity 
      per system, up to 288 DIMMs total per system 
      Sun Fire 15K: 16GB to 576GB memory capacity per system, up to 576 
      DIMMs total per system 
       
      1GB, 2GB, and 4GB memory expansion options (each a group of 4 DIMMs) 
       
      Up to eight memory expansion options per CPU/Memory board | 
  
   
    | Standard 
      Interfaces  | 
  
   
    | Ethernet | 
     One ethernet/fast ethernet (10BASE-T/100BASE-TX) standard 
      twisted-pair port (RJ-45) 
      per system controller board. | 
  
   
    | PCI | 
    Four slots per hsPCI assembly supporting up to two 33-MHz 
      and two 33/66-MHz industry standard PCI boards. | 
  
   
    | Serial | 
    One RS-232 serial TTYA port (mini-DIN8) 
      per system controller board. | 
  
   
    | Internal 
      Mass Storage | 
  
   
    | Disks (Internal - System Controller Peripheral Board) | 
    2 mirrored 18.2GB - 10000 RPM Disk Drives (system controller 
      boot disks) | 
  
   
    | Disk Arrays (External - Peripheral Cabinet) | 
    Sun StorEdge[tm] S1  * | 
  
   
    | DVD-ROM (Internal - System Controller Peripheral Board) | 
    10X DVD-ROM Drive | 
  
   
    | Tape (Internal - System Controller Peripheral Board) | 
     20-40 GB 4 mm DDS-4 Tape Drive  | 
  
   
    | * - Primary boot device for Sun Fire 12K / 15K.  | 
  
   
    | Power 
      Supplies  | 
  
   
    N+1 redundant 
      6 dual-input AC-to-48 volt DC power supplies 
      Two power cables go to each supply, so they can connect to separate power 
      grids (12 power cords) | 
  
   
    | Environment | 
  
   
    | AC power | 
     200 - 240 VAC, single phase, 47 - 63 Hz; requires 12 - 30 
      A circuits | 
  
   
    | Input power | 
    Sun Fire 12K: 12,965 W 
      Sun Fire 15K: 23,927 W | 
  
   
    | Heat output | 
    44,081 BTU /hr (up to 9 slots occupied) 
      81,352 BTU/hr (up to 18 slots occupied) | 
  
   
    | Temperature 1 | 
     Optimal: 21° C to 23° C (70° F to 74° 
      F) 
      Operating: 10° C to 35° C (50° F to 95° F) 
      Nonoperating: -20° C to 60° C (-4° F to 140° F) | 
  
   
    | Humidity | 
    Optimal: 45% to 50% relative humidity, noncondensing 
      Operating: 20% to 80% relative humidity, noncondensing 
      Nonoperating: up to 93% relative humidity, noncondensing | 
  
   
    | Altitude | 
    Operating: 3000 m (10,000 ft.) 
      Nonoperating: 12,000 m (40,000 ft.) | 
  
   
    | Plug type - U.S. & Japan | 
    NEMA L6-30P | 
  
   
    | Plug type - International | 
    IEC 309, single phase, 32 A | 
  
   
    | 1 - derate 2° C for every 1 km up to 3 km | 
  
   
     Regulations 
      Meets or exceeds the following requirements: | 
  
   
    | Safety | 
    UL 1950, CUL CAN/CSA 22:2 M950, TUV EN60950 | 
  
   
    | RFI/EMI FCC Immunity | 
    Class A, EN50021-1 Class A, EN50082-1 | 
  
   
    | Dimensions 
      and Weights | 
  
   
    | Height | 
    191.8 cm (75.5 in.) 
      203.2 cm (80.0 in.) shipping | 
  
   
    | Width | 
    84.6 cm (33.3 in.) 
      121.9 cm (48.0 in.) shipping | 
  
   
    | Depth | 
    163.8 cm (64.5 in.) 
      191.8 cm (75.5 in.) shipping | 
  
   
    | Weight | 
    Sun Fire 12K: 996.1 kg (2191.5 lb.); 1198.4 kg (2636.5 
      lb.) shipping 
      Sun Fire 15K: 1142.6 kg (2513.7 lb.); 1344.9 kg (2958.7 lb.) shipping | 
  
   
    | Power cord | 
    457 cm (15.0 ft.) | 
  
   
    | Clearance 
      and Service Access | 
  
   
    | Front | 
    111.8 cm (44.0 in.) service access | 
  
   
    | Rear | 
    111.8 cm (44.0 in.) service access | 
  
   
    Please see the Sun Fire 15K System Site Planning Guide ( 806-3510) 
      for information about proper cooling clearances and installation. |