This section provides the most common repair procedures for the 
  Netra 20, which are included in the following manual:
   
    | Component | 
     
       Remove  
         
     | 
     
       Install 
     | 
    Tips | 
  
   
    | CPU Fan Assembly | 
     
       7-5 
     | 
     
       7-7 
     | 
      | 
  
   
    | CPU Module | 
     
       9-4 
     | 
     
       9-7 
     | 
     
      
        - Guidelines for understanding and diagnosing UltraSPARC III Level 2 
          (L2) SRAM Cache Memory Errors (FIN I0887-1).
 
       
     | 
  
   
    |  
       Disk Drive (Hot Swap) 
     | 
     
       8-2 
     | 
     
       8-4 
     | 
     
      
        - Seagate ST336605FC 36GB and ST373405FC 73G drives could be susceptible 
          to label corruption (FIN I0816-1).
 
        - Recovering from a failed FCAL boot disk (SRDB 17643).
 
       
     | 
  
   
    | Disk Drive (Unmirrored Root Disk) | 
     
       8-5 
     | 
     
       8-6 
     | 
     
      
        - Seagate ST336605FC 36GB and ST373405FC 73G drives could be susceptible 
          to label corruption (FIN I0816-1).
 
        - Recovering from a failed FCAL boot disk (SRDB 17643).
 
       
     | 
  
   
    | Graphics Card | 
     
       - 
     | 
     
       - 
     | 
    
      
        - XVR-500 Graphics Accelerator card does not function properly in Netra 
          20 servers (FIN I0900-1).
 
       
     | 
  
   
    | LOMLite2 Card | 
     
       9-15 
     | 
     
       9-15 
     | 
      | 
  
   
    | Memory  | 
     
       9-9 
     | 
     
       9-11 
     | 
     
      
        - Too many Memory DIMMs are being unnecessarily replaced on UltraSPARC 
          III family of systems utilizing NG-DIMM memory (FIN I0760-1).
 
       
     | 
  
   
    | PCI Card | 
     
       9-3 
     | 
     
       9-3 
     | 
     
      
        - UltraSPARC III systems may panic due to a conflict between the Schizo 
          2.4 ASIC and the GigaSwift Ethernet PCI Card (FIN I0874-1). 
        
 
       
     | 
  
   
    | Power Distribution Board | 
     
       6-4 
     | 
     
       6-6 
     | 
      | 
  
   
    | Power Supply Unit | 
     
       6-1 
     | 
     
       6-3 
     | 
      | 
  
   
    | PSU Fans | 
     
       7-3 
     | 
     
       7-4 
     | 
      | 
  
   
    | Replaceable Batter | 
     
       9-12 
     | 
     
       9-13 
     | 
      | 
  
   
    | System Configuration Card Reader | 
     
       9-16 
     | 
     
       9-17 
     | 
      | 
  
   
    | System Board | 
     
       9-18 
     | 
     
       9-23 
     | 
     
      
        -  UltraSPARC III and III+ based platforms could be susceptible to UCC 
          errors that may cause system panics (FIN I0856-1).
 
         
       
     |