|  
       Tape Drives 
     | 
  
   
    | DLT[tm] 7000 | 
    Quantum DLT 7000 HV Differential SCSI 35 
      - 70GB Tape Drive  | 
  
   
    | DLT 8000 | 
    Quantum DLT 8000 HV Differential SCSI 40 
      - 80GB Tape Drive  | 
  
   
    | LTO | 
    LTO High Voltage Differential SCSI Tape 
      Drive  | 
  
   
    |  
       Environment 
     | 
  
   
    | AC Voltage Range | 
    100-127 VAC (autoselecting) or 200-240 VAC 
      (autoselecting) | 
  
   
    | Frequency | 
    50-60 Hz | 
  
   
    | Power Consumption | 
    L20 - 200 W (maximum) 
      L40 - 375 W (maximum) 
      L60 - 560 W (maximum) | 
  
   
    | Heat Dissipation | 
    830 BTU/hr (maximum) | 
  
   
    | Power Inlet (U.S. and Canada) | 
    IEC-320 Connector | 
  
   
    | Temperature & Humidity | 
    Operating 10 ºC to 35ºC 
      ambient (50ºF to 95ºF), 20% to 80% noncondensing relative humidity, 
      noncondensing 
      Non-Operating -40 ºC to 60ºC ambient (-40ºF to 140ºF), 
      10% to 95% relative humidity, noncondensing | 
  
   
    | Altitude | 
    0 - 10,000 feet | 
  
   
    |  
       Dimensions and Weights 
     | 
  
   
    | Item | 
    Rack-mount (without cartridges) | 
    Deskside (without cartridges) | 
  
   
    | Height  | 
    L20 - 216 mm (8.5 in) 
      L40 - 489 mm (19.25 in) 
      L60 - 711 mm (28 in) | 
    245 mm (9.7 in) 
      510 mm (20.1 in) 
      n/a  | 
  
   
    |  Width  | 
    L20 - 442 mm (17.4 in) 
      L40 - 442 mm (17.4 in) 
      L60 - 442 mm (17.4 in) | 
    488 mm (19.2 in) 
      488 mm (19.2 in) 
      n/a | 
  
   
    |  Depth  | 
    L20 - 700 mm (27.4 in) 
      L40 - 700 mm (27.4 in) 
      L60 - 760 mm (29.9 in) | 
    760 mm (29.9 in) 
      760 mm (29.9 in) 
      n/a  | 
  
   
    |  Weight  | 
    L20 - 36.8 kg (81 lb) 1 drive, 40.8 kg (90 lb) 2 drive 
      L40 - 70.9 kg (156 lb) 
      L60- 94.5 kg (208 lb) | 
    43.7 kg (96 lb) 1 drive, 47.8 kg (105 lb) 2 drive 
      80.5 kg (177 lb) 
      n/a  | 
  
   
    |  
       Regulations 
        Meets or exceeds the following requirements: 
     | 
  
   
    | Safety  | 
    UL 1950 Listed, CSA C22.2-No. 950, TUV-EN60950 60825-1 | 
  
   
    | Emission | 
    FCC Part 15B Class A, CE Mark, VCCI Class 1, C-Tick, GOST, 
      BCIQ | 
  
   
    |  
       Capacity and Performance 
     | 
    DLT 7000 | 
    DLT 8000 | 
    LTO | 
  
   
    | Number of Tape Drives | 
     L20 - 1 to 2  
      L40 - 2 to 4  
      L60 - 4 to 6  | 
    L20 - 1 to 2  
      L40 - 2 to 4  
      L60 - 4 to 6  | 
    L20 - 1 to 2 
      L40 - 2 to 4 
      L60 - 4 to 6 | 
  
   
    | Number of Cartridges | 
    L20 - 20 
      L40 - 40 
      L60 - 60 | 
    L20 - 20 
      L40 - 40 
      L60 - 60 | 
    L20 - 20 
      L40 - 40 
      L60 - 60 | 
  
   
    | Cartridge Capacity | 
    10 GB (native, type III cartridge) 
      15 GB (native, type IIIxtcartridge) 
      35 GB (native, type IV cartridge) | 
    10 GB (native, type III cartridge) 
      15 GB (native, type IIIxtcartridge) 
      40 GB (native, type IV cartridge) | 
    100 GB (native) | 
  
   
    | Library Capacity (native) | 
    L20 - 700 GB 
      L40 - 1.4 TB 
      L60 - 2.1 TB | 
    L20 - 800 GB 
      L40 - 1.6 TB 
      L60 - 2.4 TB | 
    L20 - 2 TB 
      L40 - 4 TB 
      L60 - 6 TB | 
  
   
    | Library Throughput | 
    126 GB/hour (native) | 
    n/a | 
    n/a | 
  
   
    | Drive Sustained Transfer Rate | 
    5 MB/sec (user native, maximum) | 
    6 MB/sec (user native, maximum) | 
    15 MB/sec  | 
  
   
    | Native Transfer Rate (library) | 
    L20 - 10 MB/sec 
      L40 - 20 MB/sec 
      L60 - 30 MB/sec | 
    L20 - 12 MB/sec 
      L40 - 24 MB/sec 
      L60 - 36 MB/sec | 
    L20 - 30 MB/sec 
      L40 - 50 MB/sec 
      L60 - 90 MB/sec | 
  
   
    | Host Software | 
    Solaris[tm] Operating Environement 2.6, 7, 8 
      VERITAS NetBackup software 3.2 or later (with patches) 
      Solstice Backup[tm] software 5.5.1 or later 
      Sun StorEdge Utilization Suite Recovery and Archive Service Software (formerly SAM-FS) | 
    Solaris[tm] Operating Environement 2.6, 7, 8 
        VERITAS NetBackup software 3.4 or later (with patches) 
        Solstice Backup[tm] software 5.5.1 or later 
        Sun StorEdge Utilization Suite Recovery and Archive Service Software (formerly SAM-FS) | 
    Solaris[tm] Operating Environement 2.6, 7, 8 
        VERITAS NetBackup software 3.4 or later (with patches) 
        Solstice Backup[tm] software 6.0 or later 
        Sun StorEdge Utilization Suite Recovery and Archive Service Software (formerly SAM-FS) |