| Processor | 
  
   
    | Number | 
    From one to four processor modules | 
  
   
    | Architecture | 
    450-MHz UltraSPARC[tm]-II module | 
  
   
    | Cache memory | 
    16-KB I-cache, 16-KB D-cache per processor 
       4-MB external cache per processor 
      | 
  
   
    | Datapath | 
     
       UPA operates at 112.5-MHz with 450-MHz processor 
      | 
  
   
    | Main 
      Memory  | 
  
   
    | Capacities | 
    16 DIMM module slots; four banks of four slots 
       Accepts 64- or 256-MB DIMMs 
       256-MB to 4 GB total memory capacity 
      | 
  
   
    | Memory type | 
    144-pin 5V 60-ns memory modules | 
  
   
    | Datapath | 
    576 bits wide; 512 bits data, 64 bits ECC 
       Up to 1.78-GB/sec throughput 
      | 
  
   
    | Standard 
      Interfaces  | 
  
   
    | Ethernet | 
    One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair standard 
      connector (RJ-45), self-sensing | 
  
   
    | Keyboard and mouse | 
    One standard keyboard/mouse port (mini 
      DIN-8) | 
  
   
    | Parallel | 
    One Centronics compatible parallel port (DB25); 
      ECP mode capable | 
  
   
    | PCI | 
     
       Four full-size slots compliant with PCI specification version 2.1: 
      
        - One slot operating at 33- or 66-MHz, 32- or 64-bit data bus width, 
          3.3 volt 
 
        - Two slots operating at 33 MHz, 32- or 64-bit data bus width, 5 volt
 
         
        - One slot operating at 33 MHz, 32-bit data bus width, 5 volt 
 
       
     | 
  
   
    | SCSI | 
     One 40MB/sec, 68-pin 
      ,Ultra SCSI (SCSI-3), 2 channels (synchronous)  | 
  
   
    | Serial | 
    Two RS-232C/RS423 serial ports (DB25) | 
  
   
    | Internal 
      Mass Storage | 
  
   
    | Disks | 
    Up to two 9.1-, 18.2-, or 36.4-GB disk | 
  
   
    | CD-ROM/DVD-ROM | 
     
       SunCD 32x 644-MB SCSI CD-ROM (standard; last order November 2000) 
      10X DVD-ROM (standard) 
     | 
  
   
    | Tape | 
     Optional 12 to 24-GB DDS2 4-mm or 14-GB 8-mm | 
  
   
    | Power 
      Supplies  | 
  
   
    | Type | 
    One or two N+1 redundant, hot swap universal input (one supply standard), 
      individual power cords | 
  
   
    | Output | 
    380 W | 
  
   
    | Power Bus | 
    Common, load-sharing | 
  
   
    | Environment | 
  
   
    | AC Input | 
    100 - 240 VAC, 47 - 63 Hz, 6.3 A(max) | 
  
   
    | Input Power | 
     610 W | 
  
   
    | Heat Output | 
     2080 BTU/hr | 
  
   
    | Temperature1 | 
    Operating: 5° C to 35° C (41° F to 95° F) 
      Nonoperating: -20° C to 60°° C (-4° F to 140° 
      F) | 
  
   
    | Humidity | 
    Operating: 20% to 80% relative humidity, noncondensing 
      Nonoperating: 5% to 93% relative humidity, noncondensing | 
  
   
    | Altitude | 
     Operating: 3000 m (10,000 ft.) 
      Nonoperating: 12,000 m (40,000 ft.)  | 
  
   
    | Vibration | 
     Operating: 0.2G peak, 5 - 500 Hz (swept sine) 
      0.0002 G2/Hz, 5 - 500 Hz (random) 
      vertical axis only (castered configuration), vertical and horizontal axes 
      (foot glide configuration) 
      Nonoperating: 1 G peak, 5 - 500 Hz (swept sine) 
      0.002 G2/Hz, 5 - 500 Hz (random) 
      3 perpendicular axes  | 
  
   
    | Shock | 
     Operating: 4G peak, 11 milliseconds half-sine pulse 
      Nonoperating: 15G peak, 11 milliseconds half-sine pulse  | 
  
   
    | Number of Cords | 
    1 per power supply; 2 (max) | 
  
   
    | Plug Type - U.S. | 
    NEMA 5-15P | 
  
   
    | Plug Type - International | 
    IEC 320, 10 A, 250 VAC | 
  
   
    |  1 The front and 
      rear doors of the cabinet must be 63% open for adequate air flow. | 
  
   
     Regulations 
      Meets or exceeds the following requirements: | 
  
   
    | Safety | 
    UL 1950, UL Canada C22.2 No. 950, TUV EN60950, UL CB Scheme to IEC 950 
      with full deviations | 
  
   
    | RFI/EMI | 
    FCC Class A, DOC Class B, VCCI Class B, EN55022 Class B | 
  
   
    | Immunity | 
    EN50082-1 | 
  
   
    | X-ray  | 
     DHHS 21 Subchapter J; PTB German X-ray Decree  | 
  
   
    | Dimensions 
      and Weights | 
  
   
    | Height  | 
     17.8 cm (7.0 in.) 
      43.8 cm (17.25 in.) shipping  | 
  
   
    |  Width  | 
     43.8 cm (17.25 in.) 
      60.02 cm (23.63 in.) shipping  | 
  
   
    |  Depth  | 
     69.2 cm (27.25 in.) 
      93.98 cm (37.0 in.) shipping  | 
  
   
    |  Weight  | 
     32.0 kg (71 lb.) 
      38.6 kg (85 lb.) shipping  | 
  
   
    | Power cord | 
     1.99 m (6.56 ft.) | 
  
   
    | Clearance 
      and Service Access | 
  
   
    | Front1 | 
    91.4 cm (36 in.)  | 
  
   
    | Rear1 | 
    91.4 cm (36 in.) | 
  
   
    | Right1 | 
    91.4 cm (36 in.) | 
  
   
    | Left1 | 
    91.4 cm (36 in.) | 
  
   
    | Top1 | 
    91.4 cm (36 in.) | 
  
   
    | Airflow | 
       | 
  
   
    | 1These 
      specifications refer to a sytem that is fully extended from the rack for 
      service. When in normal operation, there are no side clearance requirements 
      for the server as the air flow is from the front to rear. However, make 
      sure that any front or back cabinet doors are 63% open to allow adequate 
      airflow. This can be accomplished by removing the doors, or ensuring that 
      the doors have a perforated pattern that provides a 63% open area. See 816-1613 
      for more details. | 
  
   
    | Rack 
      Mounting  | 
  
   
    | Fits into a standard commercial 19-inch wide, 36-inch deep 
      rack |