This section provides the most common repair procedures for the 
  Enterprise 220R. The written procedures below are links to the 
Sun 
  Enterprise 220R Server Service Manual (806-1081). 
   
    | Component | 
     
       Remove 
     | 
     
       Install 
     | 
    Tips | 
  
   
    | CD-ROM Drive | 
     
      
     | 
     
      
     | 
      | 
  
   
    | CPU Module | 
     
      
     | 
     
      
     | 
     
      
        -  
          
Tuning the ecache_scan_rate parameter of the Solaris 
            cache scrubber provides improved Ecache parity error protection on 
            non-mirrored SRAM UltraSPARC II-based systems (FIN  I0755-1).  
         
        -  
          
The current diagnostic procedure to 
            identify the faulty CPU module from CPU Ecache parity errors is flawed 
            (FIN I0570-3). 
         
       
     | 
  
   
    | DC-to-DC Converter | 
     
      
     | 
     
      
     | 
      | 
  
   
    |  
       Disk Drive 
     | 
     
      
     | 
     
      
     | 
     
      
     | 
  
   
    | Fan Tray Assembly | 
     
      
     | 
     
      
     | 
      | 
  
   
    | Memory  | 
     
      
     | 
     
      
     | 
     
        
         
     | 
  
   
    | NVRAM/TOD Module | 
     
      
     | 
     
      
     | 
      | 
  
   
    | PCI Card | 
     
      
     | 
     
      
     | 
     
       
        
          -  
            
 
              SunPCi II and SunPCi IIpro cards may not respond 
                after rapid/successive power cycling (FCO  A0186-1).  
             
           
          -  
            
 
              Any PCI card may not seat properly and will cause 
                the PCI card not to be recognized by the system, rendering that 
                PCI card inoperable (FCO  A0168-1).  
             
           
          -  
            
A host system using the 375-0040-01 or -02 FC100/P 
              FC-AL PCI card to attach to FC-AL storage (StorEdge A5x00 and A3500) 
              may experience loop errors, which may affect data access to that 
              storage (FCO  A0164-1).  
           
          -  
            
Systems based on the PSYCHO chipset panic with a 
              PCI bus error (SRDB  40602). 
                
               
           
         
       
     | 
  
   
    | Power Distribution Board | 
     
      
     | 
     
      
     | 
      | 
  
   
    | Power Supply | 
     
      
     | 
     
      
     | 
     
      
        - Improper service procedures with the E220R/E420R power supplies could 
          result in system downtime. In addition, under certain circumstances, 
          the hot swapping functionality for the redundant power supplies may 
          fail (FIN I0666-1)
 
       
     | 
  
   
    | Removable Media Assembly (RMA) | 
     
      
     | 
     
      
     | 
      | 
  
   
    | System Board | 
     
      
     | 
     
      
     | 
     
        
       
     | 
  
   
    | Tape Drive | 
     
      
     | 
     
      
     | 
     
      
        - The peripheral D.C. power cable (530-2864-02) is too short to allow 
          the tape drive to be connected to D.C. power (FCO A0166-1).
 
       
     | 
  
   
    | Ultra SCSI Backplane | 
     
      
     | 
     
      
     | 
     
        
         
     |