       Disks 
     | 
  
   
    | 9GB | 
    IBM DDRS-39130 9.1GB 7200 RPM 1" Height Disk Drive 
      Fujitsu MAB3091SC 9.1GB 7200 RPM 1" Height Disk Drive 
      Seagate ST39173WC 9.1GB 7200 RPM 1" Height Disk Drive 
      Fujitsu MAE3091LC 9.1GB 7200 RPM 1" Height Disk Drive  
      Seagate ST39102LC 9.1GB 10000 RPM 1" Height Disk Drive 
      Seagate ST39103LC 9.1GB 10000 RPM 1" Height Disk Drive 
      Fujitsu MAG3091LC 9.1GB 10000 RPM 1" Height Disk Drive | 
  
   
    | 18GB | 
    Seagate ST318203LC 18.2GB 10000 RPM 1" Height Disk 
      Drive 
      Fujitsu MAG3182LC 18.2GB 10000 RPM 1" Height Disk Drive 
      IBM DGHS-18Y 18.2GB 10000 RPM 1 5/8" Height Disk Drive 
      Fujitsu MAA3182SC 18.2GB 7200 RPM 1 5/8" Height Disk Drive | 
  
   
    | 36GB | 
    Seagate ST136403LC 36.4GB 10000 RPM 1 5/8" Height 
      Disk Drive 
      Fujitsu MAF3364LC 36.4GB 10000 RPM 1 5/8" Height Disk Drive | 
  
   
    |  
       Capacity 
     | 
  
   
    | Up to 3.2TB using 18GB drives and up to 6.5TB using 36GB drives. | 
  
   
    |  
       Environment 
     | 
  
   
    | AC input | 
    200 - 240 VAC, 50 - 60 Hz, 24 A(PDU max rating) | 
  
   
    | Input power | 
    469 W(min) to 6181 W(max) | 
  
   
    | Heat output 1 | 
    1602 BTU/hr(min) to 20925 BTU/hr(max) | 
  
   
    | Temperature 2 | 
    Operating: 5° C to 35° C (41° F to 
      95° F) 
      Nonoperating: -10° C to 60° C (-14° F to 140° F) | 
  
   
    | Humidity | 
    Operating: 20% to 80% relative humidity, noncondensing 
      Nonoperating: 93% relative humidity, noncondensing | 
  
   
    | Altitude | 
    Operating: 3000 m (10,000 ft.) 
      Nonoperating: 12,000 m (40,000 ft.) | 
  
   
    | Number of cords | 
    1 | 
  
   
    | Plug type - U.S. | 
    NEMA L6-30P, 200 - 240 VAC | 
  
   
    | Plug type - International | 
    IEC 309, 32 A, 250 VAC | 
  
   
    1 - Minimum configuration: 
      Sun StorEdge-Light, min.(18-GB drives); Maximum configuration: 3x15, 36-GB 
      drives(maximum) 
      2 - If removable tape media is installed in the Sun StorEdge A3500 array 
      cabinet, the operating temperature range is 10° C to 32° C (50° 
      F to 90° F). | 
  
   
    |  
       Regulations 
        Meets or exceeds the following requirements: 
     | 
  
   
    | Safety  | 
    UL 1950, CSA C22.2-No. 950, TUV-EN60950, CB Scheme (to IEC 950 and Nordic 
      Deviations)  | 
  
   
    | RFI/EMI | 
    VCCI Class 1, FCC Class A, DOC Class A, EN55022 Class A, EN61000-3-2 | 
  
   
    | Immunity | 
    EN50082-1 | 
  
   
    | Product Label | 
    FCC Class A, VCCI Class 1, Industry Canada Class A, UL Mark, cUL Mark, 
      TUV Mark, CE Mark | 
  
   
    |  
       Dimensions and Weights 
     | 
  
   
    | Height  | 
    187 cm (73.5 in.) | 
  
   
    |  Width  | 
    61 cm (24 in.) | 
  
   
    |  Depth  | 
    93 cm (36.5 in.) | 
  
   
    |  Weight (rack with sequencers) | 
    159 kg (350 lb.) | 
  
   
    |  
       Clearance and Service 
        Access 
     | 
  
   
    | Front | 
    122 cm (48 in.) | 
  
   
    | Rear | 
    92 cm (36 in.) | 
  
   
    | Sides 1 | 
    92 cm (36 in.) | 
  
   
    | 1 - side access required for some service 
      procedure  |