Sun StorEdge[tm] A1000 Array: Repair Procedures
This section provides the most common repair procedures for the A1000.
The repair procedures are provided in the following manual:
   Sun 
  StorEdge A1000/D1000 Installation and Service Manual, Chapter 3, "Removing and 
  Replacing Components " 
 
The table below provides the page numbers that each procedure begins on. 
  
   
    |  
       Component 
     | 
     
       Page Number 
     | 
 
       Tips 
     | 
   
   
    |  
       Disk Drive 
     | 
     
        22 - 23 
     | 
     
      
        -  Swapping a disk within a clustered environment could cause issue 
          for a customer's clustered environment in the future if the disk is 
          the quorum device (FIN I0520-1 
          ) 
 
        - 18.2GB and 36GB IBM disk drives may be susceptible to early life failures 
          problem (I0724-2).
 
        - Adding new disk drives to StorEdge A1000/A3x00 arrays must be done 
          properly to avoid loss of LUNs (FIN I0782-1)
 
        - Sun StorEdge A1000/A3x00/A3500FC Arrays with RAID Manager 6 (RM6) may hang for up to 8 minutes
            when they contain more than one failed IBM disk drive (I0845-1).
 
        - Quantum (model# VK4550J or VK45J05) 4.2GB disk drives may fail to 
          spin up. (FCO A0113-3 
          ) 
 
       
 | 
   
   
    |  
       Cooling Canisters  
     | 
     
       23 - 24 
     | 
  | 
   
   
    |  
       Power Supply  
     | 
     
       25 
     | 
 
        
          -  
            A Power Supply failure on A1000/A3000 disk subsystems 
              currently results in no alarm. ( InfoDoc 21825 
              ) 
 
           -  
          Storage A1000 or D1000 (Dilbert) Power supplies fail 
            with amber LED. (FCO A0162-1 
            )
        
  
        
 | 
   
   
    |  
       Controller Board 
     | 
     
       26 - 28 
     | 
 
   
        - Boot process and controller on-line process may take hours in systems 
          with large StorEdge A3000, A3500 or A1000 configs. (FIN I0551-1 
          ) 
 
    
 | 
   
   
    | Battery  | 
     
       28 - 29 
     | 
   
       - Inaccurate battery failure analysis for Sun StorEdge A1000 Arrays may
                                             result in false alarms and unnecessary system downtime for customers, and
                                             unnecessary service calls for support personnel. (FIN I0922-1).
   | 
   
  
    | SIMM Upgrade  | 
    
       30 - 32 
     | 
  | 
   
 
 |