       Disks (System Capacity) 
     | 
  
   
    | Number of disk drives (with spares) | 
     
       9910: 5 to 48 
        9960: 5 to 512 
     | 
  
   
    | Hot spares (maximum) | 
    9910: 4 
      9960: 16  | 
  
   
    | Individual disk capacities, 3-in form factor, 10K RPM | 
    18 GB, 72 GB, 181 GB | 
  
   
    | Total raw capacity per system | 
    9910: 8.7 TB 
      9960: 94.9 TB | 
  
   
    |  
       Data Cache 
     | 
  
   
    | Maximum | 
    9910: 16 GB 
      9960: 32 GB | 
  
   
    | Minimum | 
    9910: 1 GB 
      9960: 2 GB | 
  
   
    |  
       Control Memory 
       
     | 
  
   
    | Up to 1.5 GB | 
  
   
    |  
       Logical Device Support 
       
     | 
  
   
    | Up to 4096 | 
  
   
    |  
       Client-Host Interface 
        Processors (CHIP)  
     | 
  
   
    | Number of CHIP pairs | 
    9910: Up to 3 
      9960: Up to 4 | 
  
   
    | Simultaneous data transfers per CHIP pair | 
    4 or 8 | 
  
   
    | Physical interfaces per CHIP pair | 
    4 or 8 | 
  
   
    |  
       Physical Interfaces 
        per System 
     | 
  
   
    | Physical Interfaces per System | 
    9910: 24 
      9960: 32 | 
  
   
    | Fibre Channel (fiber-optic cable) | 
    9910: 0, 4, 8, 12, 16, 20, or 24 
      9960: 0, 4, 8, 12, 16, 20, 24, 28, or 32 | 
  
   
    | Extended Serial Adapters | 
    9910: 0, 4, 8, 12, 16, 20, or 24 
      9960: 0, 4, 8, 12, 16, 20, 24, 28, or 32 | 
  
   
    |  
       Array Control Processor 
     | 
  
   
    | Number of ACP pairs per system | 
    9910: 1 
      9960: Up to 4 | 
  
   
    | Physical array paths per ACP pair | 
    8 | 
  
   
    | Maximum disks per array path | 
    9910: 12 
      9960: 32 | 
  
   
    | Simultaneous transfers per ACP pair | 
  
   
    |  
       To cache 
     | 
    9910: 4 
      9960: 8 | 
  
   
    |  
       To disk array 
     | 
    8 | 
  
   
    | Transfer rates | 
      | 
  
   
    |  
       Per disk array path 
     | 
    Up to 100 MB/sec | 
  
   
    |  
       Per ACP pair (to cache) 
     | 
    Up to 800 MB/sec | 
  
   
    |  
       Per fully configured system 
     | 
    9910: 3.2 GB/sec 
      9960: 6.4 GB/sec | 
  
   
    |  
       Environment 
     | 
  
   
    | Power | 
    9910: 3.3 kVA 
      9960 (Control Frame): 1.6 kVA 
      9960 (Array Frame): 3.7 kVA (1-4); 2.9 kVA (5-6)  | 
  
   
    | Heat | 
    9910: 3.1 kW 
      9960 (Control Frame): 1.5 kW 
      9960 (Array Frame): 3.4 kW (1-4); 2.6 kW (5-6) | 
  
   
    | Temperature & Humidity | 
     
       Operating1: 60 (16) to 90 (32), 20% to 80% relative 
        humidity. 
      Non-Operating: 14 (-10) to 109 (43), 8% - 90 % relative humidity. 
     | 
  
   
    | 1 Environmental 
      specification for operating condition should be satisfied before the disk 
      subsystem is powered on. The maximum temperature of 90°F (32°C) should be 
      strictly satisfied at the air inlet portion of the subsystem. The recommended 
      temperature range is 70-75°F (21-24°C). | 
  
   
    | Dimensions and Weights | 
  
   
    | Height  | 
    1,790 mm (70.5 in.) | 
  
   
    |  Width (with two side panels) | 
    9910: 700 mm (27.6 in.) 
      9960 (Control Frame): 750 mm (29.5 in.) 
      9960 (Array Frame): 600 mm (23.6 in.) 
     | 
  
   
    |  Depth  | 
    800 mm (31.5 in.) | 
  
   
    |  Weight  | 
    9910: 524 kg (1,153 lb.) 
      9960 (Control Frame): 451 kg (992 lb.) 
      9960 (Array Frame): 469 kg (1,031 lb.) 
     | 
  
   
    | Power Connectors | 
  
   
    | System | 
    Geography | 
    Power | 
    Quantity | 
    Plug | 
    Connector | 
  
   
    | 9910 | 
    US | 
    Single-Phase | 
     
       2 
     | 
    Russellstoll 3720DP 
      N/A - Controller  | 
    Russellstoll 3913 or Russellstoll 3743 
      N/A - Controller  | 
  
   
    | Europe | 
    Single-Phase | 
     
       2 
     | 
    N/A (Hardwire) 
      N/A - Controller | 
    N/A (Hardwire) 
      N/A - Controller | 
  
   
    | 9960 (Control Frame) | 
    US | 
    Single-Phase | 
     
       2 
     | 
    Russellstoll 3720DP | 
    Russellstoll 3913 or Russellstoll 3743 | 
  
   
    | 3-Phase | 
     
       0 
     | 
    N/A – Powered from first Array Frame | 
    N/A – Powered from first Array Frame | 
  
   
    | Europe | 
    Single-Phase | 
     
       2 
     | 
    N/A (Hardwire) | 
    N/A (Hardwire) | 
  
   
    | 3-Phase | 
     
       0 
     | 
    N/A – Powered from first Array Frame | 
    N/A – Powered from first Array Frame | 
  
   
    | 9960 (Array Frame) | 
    US | 
    Single-Phase | 
     
       2 
     | 
    Russellstoll 3720DP | 
    Russellstoll 3913 or Russellstoll 3743 | 
  
   
    | 3-Phase | 
     
       2 
     | 
    Russellstoll 3760 or Russellstoll 3760PDG | 
    Russellstoll 3754 or Russellstoll 3934 | 
  
   
    | Europe | 
    Single-Phase | 
     
       2 
     | 
    N/A (Hardwire) | 
    N/A (Hardwire) | 
  
   
    | 3-Phase | 
     
       2 
     | 
    N/A (Hardwire) | 
    N/A (Hardwire) |