       Disks (System Capacity) 
     | 
  
   
    | Number of disk drives (with spares) | 
    9970: 5 to 128 
      9980: 5 to 1024 | 
  
   
    | Hot spares (maximum) | 
    9970: 4 
      9980: 16 | 
  
   
    | Individual disk capacities, 3-in form factor | 
    36 GB (15K RPM) 
      73 GB (10K RPM) | 
  
   
    | Total raw capacity per system (36 GB drive) | 
     
       9970: 4.6 TB 
        9980: 36.8 TB 
     | 
  
   
    | Total raw capacity per system (73 GB drive) | 
    9970: 9.3 TB 
      9980: 74.7 TB | 
  
   
    |  
       Data Cache 
     | 
  
   
    | Maximum | 
    9970: 32 GB 
      9980: 64 GB | 
  
   
    | Minimum | 
    9970: 2 GB 
      9980: 4 GB | 
  
   
    | Increments | 
    9970: 2 GB 
      9980: 4 GB | 
  
   
    |  
       Control Memory 
       
     | 
  
   
    | Up to 3 GB | 
  
   
    |  
       Logical Device Support 
       
     | 
  
   
    | Up to 8192 | 
  
   
    |  
       Client-Host Interface 
        Processors (CHIP) 
     | 
  
   
    | Number of CHIP pairs | 
    9970: Up to 3 
      9980: Up to 4 | 
  
   
    | Simultaneous data transfers per CHIP pair | 
    8 | 
  
   
    | Physical interfaces per CHIP pair | 
    8 | 
  
   
    | Interface speed (fibre channel) | 
    2 GB/sec | 
  
   
    |  
       Physical Interfaces 
        per System 
     | 
  
   
    | Maximum (redundant pairs) | 
    9970: 24 
      9980: 32 | 
  
   
    | Fibre Channel (fiber-optic cable) | 
    9970: 0, 8, 16, or 24  
      9980: 0, 8, 16, 24, or 32 | 
  
   
    | ESCON | 
    9970: 0, 8, 16, or 24  
      9980: 0, 8, 16, 24, or 32 | 
  
   
    | FICON | 
    9970: 0, 8, 16, or 24  
      9980: 0, 8, 16, 24, or 32 | 
  
   
    |  
       Array Control Processor 
     | 
  
   
    | Number of ACP pairs per system | 
    9970: 1 or 2 
      9980: Up to 4 | 
  
   
    | Disks per ACP pair | 
    9970: Up to 128 
      9980: Up to 256 | 
  
   
    | Bandwidth | 
  
   
    |  
       Per fully configured system 
     | 
    9970: 7.5 GB/sec (5 GB/sec data, 2.5 GB/sec control) 
      9980: 15 GB/sec (10 GB/sec data, 5 GB/sec control) | 
  
   
    |  
       Environment 
     | 
  
   
    | Power | 
    9970: 4.87 kVA 
      9980 (Control Frame): 2.31 kVA 
      9980 (Array Frame): 7.16 kVA | 
  
   
    | Heat | 
    9970: 4.52 kW 
      9980 (Control Frame): 2.17 kW 
      9980 (Array Frame): 6.61 kW | 
  
   
    |  
       Dimensions and Weights 
     | 
  
   
    | Height  | 
    186.0 cm (73.2 in.) | 
  
   
    |  Width (with two side panels) | 
    9970: 78.2 cm (30.77 in.) 
      9980 (Control Frame): 78.2 cm (30.77 in.) 
      9980 (Array Frame): 75.0 cm (29.5 In.) | 
  
   
    |  Depth  | 
    80.0 cm (31.5 in.) | 
  
   
    |  Weight  | 
    9970: 796.0 kg (1752.0 lb.) 
      9980 (Control Frame): 553.0 kg (1216.6 lb.) 
      9980 (Array Frame): 755.0 kg (1661.0 lb.) | 
  
   
    | Power Connectors | 
  
   
    | System | 
    Geography | 
    Power | 
    Quantity | 
    Plug | 
    Receptacle (box) | 
    Connector (inline) | 
  
   
    | 9970 | 
    US | 
    Single-Phase | 
     
       2 
     | 
    Russell & Stoll 9P53U2 
      N/A - Controller  | 
    Russell & Stoll 9R53U2W 
      N/A - Controller  | 
    Russell & Stoll 9C53U2 
      N/A - Controller  | 
  
   
    | 3-Phase | 
     
       2 
     | 
    Russell & Stoll 3760DPG or 
      DDK 115J-AP8508 | 
    Russell & Stoll 3754 | 
    Russell & Stoll 3934 | 
  
   
    | Europe | 
    Single-Phase | 
     
       2 
     | 
    N/A (Hardwire) 
      N/A - Controller | 
    N/A (Hardwire) 
      N/A - Controller | 
    N/A (Hardwire) 
      N/A - Controller | 
  
   
    | 3-Phase | 
     
       2 
     | 
    N/A (Hardwire)  | 
    N/A (Hardwire)  | 
    N/A (Hardwire)  | 
  
   
    | 9980 DKC (Controller Frame) | 
    US | 
    Single-Phase | 
     
       2 
     | 
    Russell & Stoll 9P53U2 | 
    Russell & Stoll 9R53U2W | 
    Russell & Stoll 9C53U2 | 
  
   
    | 3-Phase | 
     
       0 
     | 
    N/A – Powered from first Array Frame | 
    N/A – Powered from first Array Frame | 
    N/A – Powered from first Array Frame | 
  
   
    | Europe | 
    Single-Phase | 
     
       2 
     | 
    N/A (Hardwire) | 
    N/A (Hardwire) | 
    N/A (Hardwire) | 
  
   
    | 3-Phase | 
     
       0 
     | 
    N/A – Powered from first Array Frame | 
    N/A – Powered from first Array Frame | 
    N/A – Powered from first Array Frame | 
  
   
    | 9980 DKU (Disk Array Frame) | 
    US | 
    Single-Phase | 
     
       2 
     | 
    Russell & Stoll 9P53U2 | 
    Russell & Stoll 9R53U2W | 
    Russell & Stoll 9C53U2 | 
  
   
    | 3-Phase | 
     
       2 
     | 
    Russell & Stoll RS460P9W | 
    Russell & Stoll RS460R9W or 
      Hubbell HBL460R9W or 
      Leviton 460R9W | 
    Russell & Stoll RS460C9W or 
      Hubbell HBL460C9W or 
      Leviton 460C9W  | 
  
   
    | Europe | 
    Single-Phase | 
     
       2 
     | 
    N/A (Hardwire) | 
    N/A (Hardwire) | 
    N/A (Hardwire) | 
  
   
    | 3-Phase | 
     
       2 
     | 
    N/A (Hardwire) | 
    N/A (Hardwire) | 
    N/A (Hardwire) |