Power
- 0.6 Amps @ +5Vdc
- 3.0 Watts
   
Notes 
- The Sun-4/60 CPU requires Boot PROM 1.3 Version 3.
 - This card is not compatible with Slot-3 of the Sun-4/60/65.
 - Disable the SS10 onboard Ethernet if two or more SCSI host adapters
    are installed. Use an SBE/S or FSBE/S for Ethernet.
 - FCode on SSHA 501-1759 is not compatible with the SS10, SS20, A11,
    A12, and A14. The 501-1759 was discontinued in March 1991.
 - The SS4, SS5, SS10, SS20, A11, A12, and A14 require 501-1850-02.
    Refer to BugID 1264704.
 - Add the following to /etc/system on Solaris 2.6:
 
     forceload: drv/dma 
    Refer to BugID 4078972.
  
Reference 
 
  SBus SCSI Host Adapter Installation Guide for SPARCstations,
     800-5385.
 
 
 |