System Configuration Card
Netra T1 AC200 / Netra X1 / Sun Fire V100 
    Sun Fire V120 / Netra 120
 
 
Notes:
- The System Configuration Card retains the server's MAC address,
    hostid, and NVRAM settings for transfer to a new motherboard or server.
 - To transfer the System Configuration Card to a new server:
    
    - Power down both the old and the new Netra servers.
    
 - Remove the front bezel from both the old and the new servers.
    
 - Remove the System Configuration Card from the old server and
        insert it into the new one.
    
 - Replace the front bezel on the new server. You can secure the new
        System Configuration Card by fixing a tie-wrap through the hole in
        the front mounting of the memory card reader.
    
  
  
References
 
  Netra T1 Server User's Guide, 806-5978.
- 
  Sun Fire V100 Server User's Guide, 816-2756.
 - 
  Netra 120 and Sun Fire V120 Server User's Guide, 816-2090.
 - System Configuration Card Information Sheet, 816-0405.
  
 
 |