System Configuration Card Reader
Netra T1 AC200 / Netra T1 DC200 / Sun Fire V100 
    Sun Fire V120 / Netra 120
 
 
Notes:
- The minimum operating system is Solaris 8 HW: 10/00.
 - The hostid, MAC address, and OBP environment settings are stored
    on System Configuration Card 370-4285.
 - The hostid, MAC address, and OBP environment settings are loaded
    to the Netra T1 System Board NVRAM during OBP initialization.
 - OBP will not complete initialization without a Smart Card.
 - The system will not boot until OBP initialization is complete.
 - 370-4290 is not Field Replaceable on the Sun Fire V100.
  
References
 
  Netra T1 Server User's Guide, 806-5978.
- 
  Sun Fire V100 Server User's Guide, 816-2756.
 - 
  Netra 120 and Sun Fire V120 Server User's Guide, 816-2090.
 - 
  System Configuration Card Information Sheet, 816-0405.
  
 
 |